CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.2.9
2.5.4 Enabling reporting
You must enable event reporting in the control panel and program the events and zone types for which reports are
sent. You must specify the format of the report and, in the case of voice reports, you must map each event to a
recorded message. You can map one message to a number of events. The following example enables voice
reporting to phone number 2 for a phone line cut event and assigns a voice message to this event.
1.
Navigate with the
µ¶
keys to
Control Panel>Communications>Central Station
and press
OK
.
2.
Scroll to
Phone Numbers>Phone Number 2>Protocol>Voice
and press
OK
.
3.
The keypad beeps once to confirm the change and returns to
Protocol
.
4.
Navigate with the
µ¶
keys to
Reporting>Report Codes>Communications
and press
OK
.
5.
Scroll to
Phone Line Cut>Voice Channel
and press
OK
.
6.
Scroll to the number of the message that you want to map to that zone and press
OK
.
7.
The keypad beeps once to confirm the change and returns to
Voice Channel
.
2.6 Configuring partitions
A partition is a group of zones which operate as a unit and can be armed and disarmed independently of other
partitions in the system. A partition is also known as an area. The control panel can be divided into separate
partitions with distinct zones, keypad and user codes for each partition. Arming and bypass options can be set for
each partition. To program partition settings, select
Installer Menu>Control Panel>Partition Settings.
2.6.1 Setting timers
You can specify the time in which a user must disarm or arm a system before a full alarm occurs. The following
example sets time within which the user must leave the
protected zone after arming the system (12 seconds). It also
sets the time within which the user must disarm the system (10 seconds).
1.
Navigate with the
µ¶
keys to
Control Panel>Partition Settings>Timers
>
Entry 1
and press
OK
.
2.
Enter 12 and press
OK
.
3.
The keypad beeps once to confirm the change and returns to
Entry 1
.
4.
Scroll to
Exit 1
and press
OK
.
5.
Enter 10 and press
OK
.
Entry 1
Exit 1
Entry 2
Exit 2
Arming
Quick Arm
Re-exit
Silent Auto Arm
Silent Exit Always
Arming with Zone Lost
Miscellaneous
Silent PA (7+9)
Audible PA (7+9)
Fire/Aux 1 (1+3)
Medical/Aux 2 (4+6)
Multi Code Tamper
LED Extinguish
Bypass
Auto Bypass
Code Required
Sounder Alert
Bypass Toggle
Mains/Batt Sounder Alert
Zone Lost Gives Tamper
Timers
Feature Select
2.5.1
2.5.2
2.5.1.1
2.5.1.2
2.5.1.3
2.5.1.4
2.5.2.1
2.5.2.2
2.5.2.3
2.5.2.4
2.5.2.1.1
2.5.2.1.2
2.5.2.1.3
2.5.2.1.4
2.5.2.1.5
2.5.2.2.1
2.5.2.2.2
2.5.2.2.3
2.5.2.2.4
2.5.2.2.5
2.5.2.2.6
2.5.2.3.1
2.5.2.3.2
2.5.2.3.3
2.5.2.3.4
2.5.2.4.1
2.5.2.4.2
Keypads