CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.9.5
9.3 Programming the CS534 listen-in module
You must enroll and default the CS534 module before you begin to program the system. For more information
on enrolling and defaulting, see chapter 6. To program the CS534, select
Installer Menu>CS534 Listen-in
Module.
9.3.1 Configuring listen-in options
You can configure the listen-in mode and listen-in options. The following example prevents the central station
turning on the speaker at the premises if a duress, silent panic or hold-up alarm is reported by the control panel.
1.
Navigate with the
µ¶
keys to
CS534 Listen-in Module>Feature Select
and press
OK
.
2.
Scroll to
Speaker Lockout>Yes
and press
OK
.
3.
The keypad beeps once to accept the change and returns to
Speaker Lockout
.
9.3.2 Programming timers
You can set timers to control various CS534 listen-in module features. The following example sets the line hold
digit to 2 and line hold timeout to 60 seconds.
1.
Navigate with the
µ¶
keys to
CS534 Listen-in Module>Line Hold Digit
and press
OK
.
2.
Select
2
and press
OK
.
3.
The keypad beeps once to confirm the change and returns to
Line Hold Digit
.
4.
Scroll to
Timers>Line Hold Timeout
and press
OK
.
5.
Select
60
and press
OK
.
6.
The keypad beeps once to confirm the change and returns to
Line Hold Timeout
.
9.3.3 Setting volume levels
You can adjust volume levels used with the CS534 listen-in module. The following example sets the volume for
high gain listen in to level 4.
Timers
Mode
Listen-in Only
Speaker Lockout
Mic A at Startup
Mic B at Startup
Answer Machine Defeat
Status Check
Arming/Disarming
Feature Select
X-10 Devices
Volumes
Model
Version
Default Settings
Low Gain Listen In
High Gain Listen In
Speaker
Call Back Code
Line Hold Digit
Wrong PIN Digit Entries
Rings to Answer
Device 1
9.1
9.2
9.6
9.5
9.4
9.3
9.7
9.8
9.9
9.11
9.10
9.1.1
9.1.2
9.1.3
9.1.4
9.1.5
9.1.6
9.1.7
9.1.8
9.6.1
9.6.2
9.6.3
9.6.4
9.6.5
9.6.6
9.6.7
9.7.1
9.7.2
9.7.3
9.8.1
Line Hold Timeout
New Trip Hangup Time
Call Back Window Timer
Session Timeout
Indicator-A Time Remaining
Anti-Lock-Up Tone Time
Indicator-B Time Remaining
Module Number
House Code
9.8.1.1
Devices 2 - 9
Same as above
9.8.1.2