CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.2.27
2.4.5.2
Features 2
A menu option that allows you to configure your own reporting protocol based
on the options enabled.
2.5
Partition Settings
A menu entry that groups all partition settings. These settings include partition
features, partition timers and so on.
2.5.1
Timers
A menu entry that groups timer options.
2.5.1.1
Entry 1
A menu option that sets the time within which the user must disarm the system
before a full alarm occurs. This time can be between 10 and 255 seconds.
2.5.1.2
Exit 1
A menu option that sets the time within which the user must leave the
protected zone after arming the system before a full alarm occurs. This time
can be between 10 and 255 seconds.
2.5.1.3
Entry 2
A menu option that sets the time within which the user must disarm the system
before a full alarm occurs. This time can be between 10 and 255 seconds.
2.5.1.4
Exit 2
A menu option that sets the time within which the user must leave the
protected zone after arming the system before a full alarm occurs. This time
can be between 10 and 255 seconds.
2.5.2
Feature Select
A menu entry that groups all optional features relating to partitions.
2.5.2.1
Arming
A menu entry that groups the arming characteristics of the selected partition.
2.5.2.1.1
Quick Arm
A menu option that enables the function keys for part arming and for full
arming. These options work on a single-area keypad only.
2.5.2.1.2
Re-exit
A menu option that enables the exit delay without disarming the system.
The exit delay can be restarted if in arm stay mode by using the Arm Away
command in the user menu or by pressing a function key programmed by the
installer to activate arm away.
2.5.2.1.3
Silent Auto Arm
A menu option that arms the system automatically at a preset time without the
keypad buzzer sounding.
2.5.2.1.4
Silent Exit Always
A menu option that prevents the exit time buzzer activating whenever the
system is armed or during the re-exit time.
2.5.2.1.5
Arming with Zone Lost
A menu option that allows the system to be armed when RF zones have not
reported to the RF receiver for a period longer than the normal supervision
window. When this option is disabled, the system cannot be armed when an
RF zone is lost.
2.5.2.2
Keypads
A menu entry that groups keypad options.
2.5.2.2.1
Silent PA (7+9)
A menu option that prevents all audible and visual indications when a personal
attack alarm occurs.
2.5.2.2.2
Audible PA (7+9)
A menu entry that causes the keypad to beep and sounds the internal and
external sirens when a PA alarm is activated.
2.5.2.2.3
Fire/Aux 1 (1+3)
A menu option that activates keys 1 and 3 as the fire alarm combination keys.
When this option is enabled and these keys are pressed at the same time, a
fire alarm is generated.
2.5.2.2.4
Medical/Aux 2 (4+6)
A menu option that activates keys 4 and 6 as the medical alarm combination
keys. When this option is enabled and these keys are pressed at the same
time, a medical alarm is generated.
2.5.2.2.5
Multi Code Tamper
A menu option that disables the keypad for 60 seconds and sends a tamper
signal to the central station if 30 key presses are entered without producing a
valid code.
2.5.2.2.6
LED Extinguish
A menu option that enables or disables LED Extinguish for all partitions.
Location
Term
Definition