CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.2.17
2.2.1.1.2
Time Unit
A menu option that specifies whether the outputs are timed in minutes or
seconds.
2.2.1.1.3
Time
A menu option that sets the length of time for which an output is activated. If it
is set to 0, the output follows the event.
2.2.1.1.4
Partitions
A menu entry that lists the partitions assigned to the selected output. The
selected output can be triggered by an event on these partitions.
A zone may reside in any combination of partitions. A zone that resides in
more than one partition becomes a common zone and is reported to its lowest
partition number. A common zone is armed only when all the partitions that it
belongs to are armed. It is disarmed the moment one of the partitions it
belongs to is disarmed.
2.2.1.1.5
Attributes
A menu entry that groups the programmable attributes of the selected output.
2.2.1.1.5.1
Latched
A menu option that causes an output to remain activated until a code is
entered at the keypad.
2.2.1.1.5.2
Code Stops Timer
A menu entry that allows the timer used on programmable outputs to be reset
by entering a valid user code.
2.2.1.1.5.3
Only if Closed
A menu option that activates an output after closing time and before opening
time. During these times, codes can be used to arm/disarm the system. A
timer is used to set these times.
2.2.1.1.5.4
Only if Open
A menu option that activates an output between opening time and closing
time.
2.2.1.1.5.5
Inverted
A menu option that enables a mode that inverts the state of an output
(normally activated and then deactivated when an event occurs).
2.2.2
Internal Siren
A menu entry that groups options that set the conditions/events that activate
the internal siren. This is a siren which sounds within the building.
2.2.2.1
Sounds On
A menu entry that groups events that activate the internal siren.
2.2.2.1.1
Phone Line Cut
A menu entry that groups options that activate the internal siren when a phone
line cut event occurs.
2.2.2.1.1.1
When Armed
A menu option that activates the internal siren if a phone line cut event occurs
while the system is armed.
2.2.2.1.1.2
When Disarmed
A menu option that activates the internal siren if a phone line cut event occurs
while the system is disarmed.
2.2.2.1.2
Tampers
A menu option that activates the internal siren when a tamper occurs.
2.2.2.1.3
Expander Trouble
A menu option that activates the internal sound when an expander trouble
condition occurs.
2.2.2.2
Short Blast On
A menu entry that groups internal sounder options. Each option specifies a
time at which the sounder blasts. These options are: Arming, Exit Expiry,
Closing Kissoff and Keyswitch Arming.
2.2.2.2.1
Arming
A menu option that causes the internal sounder to blast when the system
arms.
2.2.2.2.2
Exit Expiry
A menu option that causes the internal sounder to blast when the exit time
expires.
2.2.2.2.3
Closing Kissoff
A menu option that causes the internal sounder to blast when the central
station receives a closing report.
2.2.2.2.4
Keyswitch Arming
A menu option that causes the internal sounder to blast when the system is
armed by keyswitch or armed and disarmed by keyswitch. There is one blast
for arming and two blasts for disarming.
Location
Term
Definition