CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.9.4
9.2.4 Tones
These indicator tones may be heard at the central station during a two-way session. The definition of these
indicator tones is as follows:
LOW = 400 HzMID = 1000 Hz.................................... HIGH = 1600 Hz
Level
6
Output / relay control level (positive—turn
Note: This feature requires X-10 Interface.
0
Returns to the initial session settings when it is tripped. This includes the microphone
selection and audio mode.
1 - 9
Turns the corresponding output/relay ON. A positive tone sounds.
Level
7
Status check
0
Returns to the initial session settings when it is tripped. This includes the microphone
selection and audio mode.
1
Armed status: If partition 1 is armed, a positive tone sounds. If disarmed, a negative tone
sounds.
2
Ready status: If partition is in Ready status, a positive tone sounds. If it is not Ready, a
negative tone sounds.
3
Power status: If AC and battery are good, a positive confirmation tone sounds. If either
AC or battery is bad, a negative tone sounds.
4 – 9
Extends the session time.
Level
8
Arming / disarming partition 1
0 – 9
Enter your PIN user code to arm or disarm the system. If partition 1 is armed, a positive
beep sounds. If partition 1 is disarmed, a negative beep sounds.
Table 9-3: CS534 tones
Tone
Description
One high tone for 100 mS
Time remaining indicator “A “.
One mid tone for 100 mS
Time remaining indicator “B”.
One mid tone for 100 mS, off for 100 mS, one high tone for
100 mS
New alarm alerts for the same partition.
One high tone for 100 mS, off for 100 mS, one mid tone for
100 mS, off for 100 mS, one high tone for 100 mS
New alarm alerts for a different partition.
Continuous on/off high tone every 100 mS; will stop after a
digit is received
System waiting for access PIN.
One low tone for 200 mS (if enabled)
Anti lock-up
One mid tone for 500 mS
Acknowledgement to level change command.
One mid tone for 250 mS, off for 250 mS, one mid tone for 250
mS, off for 250 mS, one mid tone for 250 mS
Error tone
One low tone for 100mS
Relay / Output turned ON, or
Positive Status response, or
Partition 1 armed.
One low tone for 100mS; off for 200mS; one low tone for 100
mS
Relay / Output turned OFF, or
Negative Status response, or
Partition 1 disarmed.
Table 9-2: CS534 control levels