10. MAINTENANCE, TROUBLESHOOTING
10-11
10.10.5 Rx test (For service technician)
This test inputs dummy data to each board and each board outputs a test
pattern (32 color). Select RX TEST at the TEST menu and press the [MENU] key.
Select the board to test with the [MODE] key, in the sequence shown below.
BMFTEST
SCAN-H TEST
Horizontal display
SCAN-H&V TEST
Horizontal display
Vertical display
IFES TEST
Echo Sounder display
Horizontal combination dislpay
DUAL TEST
History display
<<CHECKING RX >>
PRESS MENU KEY TO QUIT TEST MODE.
MODE : CHANGE DISP MODE.
This message appears while the Rx test is
being conducted.
SCAN2-H TEST
Horizontal 2 display
SCAN2-H & V TEST
Vertical display
Rx test sequence, Rx test message
10.10.6 Noise test (For service technician)
This test measures noise level. Select NOISE TEST at the TEST menu and
press the [MENU] key. The following message appears on the display while the
test is being conducted. Use the [GAIN] control to adjust noise level to medium.
<< NOISE TEST >>
PRESS MENU KEY TO QUIT TEST MODE.
ADJUST NOISE LEVEL TO MEDIUM BY GAIN KNOB.
Noise test message
Summary of Contents for FSV-30
Page 1: ...COLOR SCANNING SONAR FSV 30 ...
Page 14: ...This page is intentionally left blank ...
Page 30: ...1 OPERATIONAL OVERVIEW 1 16 This page is intentionally left blank ...
Page 80: ...2 HORIZONTAL MODE 2 50 The page is intentionally left blank ...
Page 100: ...3 VERTICAL MODE 3 20 The page is intentionally left blank ...
Page 122: ...5 6 This page is intentionally left blank ...
Page 136: ...7 10 This page is intentionally left blank ...
Page 152: ...8 OTHERS MENU 8 16 This page is intentionally left blank ...
Page 170: ...10 MAINTENANCE TROUBLESHOOTING 10 14 This page is intentionally left blank ...
Page 174: ...SP 4 This page is intentionally left blank ...
Page 182: ...ORIGINAL SETTING AP 8 New Original setting ...
Page 183: ...ORIGINAL SETTING AP 9 ...
Page 184: ...ORIGINAL SETTING AP 10 ...
Page 185: ...ORIGINAL SETTING AP 11 Color setting ...
Page 186: ...ORIGINAL SETTING AP 12 Color Response Curve setting ...