C122-E001-10EN
2-23
2.2 MMB Connection and Setup
Setting e-mail reporting
• Procedure
1
Click [Network Configuration]
→
[Alarm E-Mail].
The [Alarm E-Mail] window is displayed.
Figure 2.12 [Alarm E-Mail] window
2
Specify the required items.
Table 2.8 Displayed and setting items in the [Alarm E-mail] window
3
Click the appropriate button.
•
To set e-mail sending conditions: Click the [Filter] button.
•
To enable the setting: Click the [Apply] button.
•
To send e-mail for testing: Click the [Test
] button.
Note:
A DNS server must be specified prior to specifying a fully qualified
domain name (FQDN). You can specify it by selecting [Network
Configuration]
→
[Network Interface].
Item
Description
Alarm E-Mail
Specifies whether to transmit an Alarm E-Mail if an event
occurs. To specify transmission, select [Enable].
From:
Sets the E-Mail address of the sender.
To:
Sets the E-Mail address of the recipient.
SMTP Server
Sets an SMTP server IP address or FQDN. Note that the
FQDN can be set only when a DNS has been set.
Subject
Sets the subject of the mail.
Summary of Contents for PRIMEQUEST 400 Series
Page 1: ...C122 E001 10EN Front Cover INSTALLATION MANUAL ...
Page 2: ......
Page 18: ...x C122 E001 10EN NOTE ON SAFETY Extended Power Cabinet ...
Page 19: ...C122 E001 10EN xi NOTE ON SAFETY Extended I O Cabinet ...
Page 20: ...xii C122 E001 10EN NOTE ON SAFETY PCI_Box ...
Page 21: ...C122 E001 10EN xiii NOTE ON SAFETY PRIMEQUEST 520A 520 420 Main unit ...
Page 22: ......
Page 24: ......
Page 42: ......
Page 46: ......
Page 122: ......
Page 186: ......
Page 354: ......
Page 356: ......
Page 394: ......
Page 428: ......
Page 445: ......
Page 446: ...Back Cover ...