5.1.1
Access control setting
To ensure MMB security, access control for a network protocol is set.
Fujitsu recommends setting access control during installation to ensure security.
However, access control can be set later.
Selecting a filter to be edited
• Procedure
1
Click [Network Configuration]
→
[Access Control].
The [Access Control] window is displayed.
Figure 5.1 [Access Control] window (example)
2
Use a radio button to select a filter to be edited.
Table 5.1 Displayed and setting items in the [Access Control] window
Item
Description
Protocol
Displays protocols subject to IP filtering.
HTTP, HTTPS, Telnet, SSH, SNMP
Access Control
Displays setting for enabling/disabling access.
IP Address
Connection-enabled IP address
Subnet Mask
Subnet mask of connection-enabled IP address