4.5 PSA Installation (Windows Server 2003) (PRIMEQUEST 580A/540A/580/540/480/440)
4
SNMP security setting
Make SNMP Service security settings because PSA must receive
SNMP packets from the MMB.
The subsequent operations varies as follows depending on the
parameter selected on the [Security tab] in the [Properties] dialog box
of [SNMP Service] during PSA installation:
•
If [Accept SNMP packets from any host] was selected:
The SNMP security settings need not be made.
•
If [Accept SNMP packets from these hosts] was selected:
Make sure SNMP security settings unless the IP address of the MMB
and localhost parameter are not specified.
Note:To change the SNMP Service security setting from [Accept
SNMP packets from any host] to [Accept SNMP packets from
these hosts] after PSA installation, or to change the IP address
of the MMB, execute the SNMP security setting command
(setsnmpsec). For details on this command, see the
PRIMEQUEST 580A/540A/520A/500/400 Series Reference
Manual: Basic Operation/GUI/Commands (C122-E003EN).
5
Window Management Instrumentation (WMI) setting
PSA collects information on PCI cards and SCSI devices by using
WMI, which is installed as standard with Windows.
If the amount of memory and the number of internal handles that WMI
uses to collect this information are insufficient because there are many
LUNs, such as in RAIDs, change settings to the following values:
•
Maximum amount of memory used: 536,870,912 bytes
•
Maximum number of internal handles: 65,536
6
Task scheduler settings
To monitor for errors involving the power supply of the expansion file
unit and FANs, make the following task scheduler settings:
Task name: File Unit Status Check
Activation interval: 5 minutes
The configuration information is collected when the PSA is started.
Error monitoring is then performed based on the collected information
until the next time the PSA is started. If an expansion file unit is not
connected, configuration information is collected according to the
schedule, but the process is completed immediately without error
monitoring performed. Therefore, no additional workload is imposed
on the system.
Summary of Contents for PRIMEQUEST 400 Series
Page 1: ...C122 E001 10EN Front Cover INSTALLATION MANUAL ...
Page 2: ......
Page 18: ...x C122 E001 10EN NOTE ON SAFETY Extended Power Cabinet ...
Page 19: ...C122 E001 10EN xi NOTE ON SAFETY Extended I O Cabinet ...
Page 20: ...xii C122 E001 10EN NOTE ON SAFETY PCI_Box ...
Page 21: ...C122 E001 10EN xiii NOTE ON SAFETY PRIMEQUEST 520A 520 420 Main unit ...
Page 22: ......
Page 24: ......
Page 42: ......
Page 46: ......
Page 122: ......
Page 186: ......
Page 354: ......
Page 356: ......
Page 394: ......
Page 428: ......
Page 445: ......
Page 446: ...Back Cover ...