100/180MM DISTRIBUTED GRAPHIC RECORDER: USER GUIDE
HA029324
Issue 11 Oct 14
User Guide
Page 251
7.3.2 Advanced parameters
The selection of the Advanced properties set, is carried out from the Properties Options page as described
in
section 7.2.3
, above. Advanced properties are in addition to the basic properties described above, not a
replacement for them.
Table 7.3.2 Advanced edit level parameters (sheet 1 of 6)
Parameter
Pick list content
Description
3D effect
Enable/Disable
For Channel numeric display only, adds an embossed boxed surround
to the display. Applies only if ‘Custom’ selected as Faceplate style.
Alarm marks colour None
Allows a colour to be selected for alarm marks on trend scales. Default
is colour 0 (red).
Bargraph style
Single Line...
For horizontal bargraphs only. ‘Plain’ produces a bargraph with de-
scriptor to the left of the bar, digital value to the right of the bar,
and alarm indication to the right of the decimal value. ‘With units’
adds units after the digital value. ‘3D’ adds an embossed boxed sur-
round. ‘Scale’ adds a scale below the bar, with end-point values and
tick points. Scale style (described below) may be used to modify the
appearance of the scale.
Faceplate below bar Produces coloured bar above channel descriptor, digital value and
alarm indication. No scale is printed
Just bar
Produces a colour bar with no textual information, or just the low and
high scale values, according to component.
Bar and scale
Produces a colour bar with a scale, but no digital value or alarm indica-
tion
Default
Produces a colour bar with scale, with descriptor, digital value and
alarm indication above.
Default Vertical Bargraph Produces a colour bar with a scale
System Vertical Bargraph Produces a colour bar with a scale
Horizontal Bargraph Produces a colour bar with scale, with descriptor, digital value and
alarm indication above.
Best Fit Font
Enabled/Disabled
For Channel numeric only. Applies only if ‘Custom’ selected as Face-
plate style. If enabled, the display fonts for descriptor, value and units
are selected by the instrument to suit the screen scale. The fonts will
thus vary in size according to the size of the Channel Numeric display.
Overridden by any settings for Value Font, Descriptor Font or Units
Font other than ‘Default’.
Channel cycle time 10
For group trend displays, allows a time period, in seconds, to be en-
tered for channel scroll rate. 0= no scroll.
Colour Alarms
None
Used only when Colour style = ‘Channel alarms’. A semicolon-sepa-
rated list of (Colour channel) alarms, used to change the colour of the
component being con
fi
gured according to alarm status. Colours are
de
fi
ned in ‘Colour Backgrounds’ and ‘Colour Foregrounds’, described
below.
Colour Backgrounds None
Used only if Colour style = ‘Channel Alarms’ or ‘Channel thresholds’. A
semicolon-separated list of background colours for the component be-
ing con
fi
gured. The number of colours entered must match the num-
ber of alarms or threshold values as appropriate. Overrides any entry
in ‘Background Colour’. Colours are entered by touching each required
selection in turn. The semicolon separators are entered automatically,
in front of each selection (apart from the
fi
rst).
Colour channel
All channels
Allows a channel to be de
fi
ned to be used in percentile or quartile
fi
ll-
ing or as a source of channel thresholds or channel alarms, as selected
in ‘Colour style’, below.
Summary of Contents for 6100
Page 2: ......
Page 4: ...EUROT H ERM ...
Page 377: ...100 180 MM DISTRIBUTED GRAPHIC RECORDER USER GUIDE This page is de ...