100/180MM DISTRIBUTED GRAPHIC RECORDER: USER GUIDE
HA029324
Issue 11 Oct 14
User Guide
Page 255
Scale style
Scale on bar.---
See the
fi
gure below for clari
fi
cation. For vertical bargraphs only.
No Text
Produces scale tick marks, but without values
Decimal scale
For bargraphs, produces scale with 9 divisions (0, 10, 20, 30, 40, 50, 60,
70, 80, 90, 100% of scale width). Zero and full scale values printed. For
Horizontal bargraphs, each scale division has 4 minor divisions (0, 20,
40, 60, 80, 100 % of major division).
Default
Uses scale information from each point’s scale con
fi
guration
Horizontal Bargraph
As default for horizontal bargraphs
Horizontal Faceplate Produces faceplate display with scale end points, descriptor, digital
value and alarm indicator
Vertical bargraph
As default for vertical bargraphs.
Show Alarm Marks Yes/No
Allows channel scale alarm marks to be displayed (yes) or not (no).
Alarm Marks Colour, described above, allows the user to select a col-
our for the alarm marks.
Time Marker colour Default
Allows a colour to be selected for time/date printing on a trend chart
Table 7.3.2 Advanced edit level parameters (sheet 5 of 6)
7.3.2 ADVANCED PARAMETERS (Cont.)
Time Marker interval Default
Number of horizontal grid lines between successive time markers.
Trend Padding
Default
For group trend only. Normal trends are 1 pixel wide. Setting a pad-
ding value of N, adds N pixels on each side of the central pixel. For
example, a padding value of 2 would produce traces 5 pixels wide.
Applies to all channels in the group.
Units Font
List of fonts
For Channel Numeric displays only, if Faceplate Style is set to ‘Custom’,
then Units Font allows the Channel Units font to be selected from a
picklist.
Update when
Value changes
Action is taken when the value associated with the component changes
Always
The component is redrawn, continuously, at the display update rate.
Vertical alignment
Centred/bottom/top Allows text to be positioned relative to its height setting
Value Font
List of fonts
For Channel Numeric displays only, if Faceplate Style is set to ‘Custom’,
then Value Font allows the Channel Value font to be selected from a
picklist.
Vertical Grid Total
Default
Number of vertical divisions for trend chart. If left at default uses the
value entered in Group Con
fi
guration (
section 4.3.2
). Any other setting
overrides Group Con
fi
guration entry
Vertical Minor Divs Default
Allows the user to enter a number of minor grid divisions. If left at de-
400.00
440.00
480.00
520.00
560.00
600.00
640.00
680.00
720.00
760.00
800.00
Scale on bar
Value 10
Scale on bar
Value 12
400.00
433.00
467.00
533.00
567.00
600.00
633.00
700.00
733.00
767.00
800.00
667.00
500.00
0
10
20
30
40
50
60
70
80
90
100
Scale on bar Percent
0
10
20
30
40
50
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
Right
Left
Centre
400.00
800.00
Decimal scale
400.00
800.00
Vertical
Bargraph
The examples below are alternatives - only one style can be chosen for each group bargraph display.
Parameter
Pick list content
Description
Summary of Contents for 6100
Page 2: ......
Page 4: ...EUROT H ERM ...
Page 377: ...100 180 MM DISTRIBUTED GRAPHIC RECORDER USER GUIDE This page is de ...
Page 396: ......