100/180MM DISTRIBUTED GRAPHIC RECORDER: USER GUIDE
HA029324
Issue 11 Oct 14
User Guide
Page 324
When used with a programmable receiver which is con
fi
gured to generate GPS messages typically every 10
minutes, the ‘Timeout’ parameter can be set to 0 to disable it, so as to record required messages every 10 min-
utes.
‘Timeout’ can be set to different rates for each
fi
lter in which case the data will be recorded at the rates set
for each
fi
lter.
When the instrument reboots the
fi
lter timeouts will reset, so the
fi
rst message received will be recorded (in a
new history
fi
le), the timeouts will then come into effect.
Filter timeouts will also be reset when the instrument is recon
fi
gured or the clock is changed as per existing
“ASCII input” parameters.