EPSON EPL-N3000/AcuLaser M4000N
Revision C
Disassembly and Assembly
550 Paper Feeder
231
Confidential
Installation
1.
Install the CLUTCH ASSY PH to the SHAFT FEED, and secure it with the E ring.
2.
Connect the connector (P/J247) of the CLUTCH ASSY PH to the HARNESS
ASSY TRAY 2. After connection, insert the connector between the ribs of the
CHUTE OUT.
3.
Secure the PLATE TIE to the CHUTE OUT with the six screws (gold, tapping,
8mm).
4.
Install the 550 FEEDER ASSY. (p.224)
5.
Install the 150 FEEDER ASSY. (p.211)
6.
Install the CHUTE TRANSFR. (p.255)
7.
Install the FAN MAIN. (p.293)
8.
Install the COVER REAR. (p.167)
9.
Install the FUSER ASSY. (p.253)
10.
Install the COVER REAR 500. (p.270)
C A U T I O N
Pay attention to the leading of the harness for the CLUTCH ASSY
PH.
C A U T I O N
Fit the cut portion of the CLUTCH ASSY PH on the boss of the
CHUTE OUT.
Summary of Contents for AcuLaser M4000N
Page 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 404: ...Confidential C H A P T E R 6 MAINTENANCE ...