1.
Install the HSG LOWER DUP to the COVER HSG DUP with the two SCREWs
HINGE.
2.
Install the SPRING DAMPER to the COVER HSG DUP with the SCREW
TAPPING.
3.
Secure the HARNESS ASSY DUP with the harness clamp as shown in the figure.
4.
Secure the HARNESS ASSY DUP EARTH with the one screw (silver, 6mm).
5.
Connect the connector of the HARNESS ASSY DUP to the PWBA DUPLEX.
6.
Install the COVER RIGHT. (p.354)
7.
Install the COVER LEFT. (p.353)
C H E C K
P O I N T
When installing the COVER RIGHT, match its positioning holes
with the bosses of the COVER HSG DUP.
C H E C K
P O I N T
When installing the COVER LEFT, match its positioning holes
with the bosses of the COVER HSG DUP.