1.
Secure the PWBA DUPLEX to the COVER HSG DUP with the two screws (gold,
tapping, 8mm x1, gold, 6mm x1).
2.
Connect the harness connectors to the connectors (P/J50, P/J51, P/J52, P/J53, P/
J54) of the PWBA DUPLEX.
3.
Install the COVER TOP. (p.346)
4.
Install the COVER RIGHT. (p.354)
5.
Install the COVER LEFT. (p.353)
C H E C K
P O I N T
Install the PWBA DUPLEX to the COVER HSG DUP in the
orientation shown in the figure.
(Refer to Figure 4- 148)
In the place of the Screw (A) shown in the figure, tighten the
screw of gold, 6mm.
(Refer to Figure 4- 148)
C H E C K
P O I N T
When installing the COVER TOP, match its positioning holes with
the bosses of the COVER HSG DUP.
C H E C K
P O I N T
When installing the COVER RIGHT, match its positioning holes
with the bosses of the COVER HSG DUP.
C H E C K
P O I N T
When installing the COVER LEFT, match its positioning holes
with the bosses of the COVER HSG DUP.