EPSON EPL-N3000/AcuLaser M4000N
Revision C
Disassembly and Assembly
Option 550 Paper Feeder
319
Confidential
4.11.15 CLUTCH PR-REGI
Removal
1.
Remove the 550 FEEDER OPTION. (p.311)
2.
Remove the six screws (gold, tapping, 8mm) securing the PLATE TIE.
3.
Remove the PLATE TIE from the CHUTE OUT.
4.
Disconnect the connector (P/J854) of the CLUTCH PR-REGI from the
HARNESS ASSY CLSNR1.
5.
Remove the E-ring retaining the CLUTCH PR-REGI and remove the CLUTCH
PR-REGI from the ROLL ASSY TURN.
Installation
1.
Install the CLUTCH PR-REGI to the ROLL ASSY TURN, and secure it with the
E ring.
2.
Connect the connector (P/J854) of the CLUTCH PR-REGI to the HARNESS
ASSY CLSNR1.
3.
Install the PLATE TIE to the CHUTE OUT with the six screws (gold, tapping,
8mm).
4.
Install the 550 FEEDER OPTION. (p.311)
Figure 4- 123. CLUTCH PR-REGI Removal
C A U T I O N
When installing it, match the notch of the CLUTCH PR-REGI to
the boss of the CHUTE OUT.
C A U T I O N
Place the connected connector between the ribs of the CHUTE
OUT.
JG3516AA
CHUTE OUT
CLUTCH PR-REGI
PLATE TIE
CONNECTOR
CHUTE OUT
WHEN ASSEMBLING
4)
3)
2)
5)