Confidential
3.4.1 LVPS
Table 3-60. Troubleshooting for LVPS
Step
Action and Question
Yes
No
Parts below can be the source of this error (
Chapter 4 Disassembly and Assembly
)
• LVPS
(p.287)
• HVPS/MCU
(p.301)
• HARNESS ASSY LVPS
1
LVPS control power
1.
Remove the SHIELD PLATE LVPS.
(p.285)
2. Disconnect P/J41 from the LVPS.
(Refer to
“Connectors
(p.406)”
)
3. Turn on the main power.
4. Measure the voltages between the following pins of
P/J41 to see if the values are as follows:
P/J41-1
↔
P/J41-2
3.3V
P/J41-4
↔
P/J41-3
5V
♦
Are the voltages between the pins of P/J41 as specified?
Go to Step 2 Replace the LVPS
2
LVPS drive power
1. Disconnect P/J42 from the LVPS.
2. Turn on the main power.
3. Measure the voltages between the following pins of
P/J42 to see if the values are as follows:
P/J42-1
↔
P/J42-2
24V
♦
24V between P/J42-1
↔
P/J42-2?
Go to Step 3
Go to
3.4.7
INTERLOCK S/W
24V
(p.119)
or
3.4.9
INTERLOCK S/W
REAR
(p.121)
or
3.4.10 SWITCH
I/L ASSY
(INTERLOCK S/
W FRONT R)
(p.121)
3
HARNESS ASSY LVPS
1. Turn off the main power.
2. Disconnect the P/J11 from the HVPS/MCU.
3. Disconnect the P/J41 from the LVPS.
♦
Is there continuity in each wiring between P/J11
↔
P/J41?
Go to Step 4
Replace the
HARNESS ASSY
LVPS
4
AC Power Supply
1. Check the AC power connection.
♦
Is the AC power cable connected and grounded properly?
Replace the
HVPS/
MCU
Notify the
customer or its
electrical engineer.
Summary of Contents for AcuLaser M4000N
Page 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 404: ...Confidential C H A P T E R 6 MAINTENANCE ...