EPSON EPL-N3000/AcuLaser M4000N
Revision C
Troubleshooting
Troubleshooting for Individual Units
112
Confidential
3.4.2 MAIN MOTOR
Table 3-61. Troubleshooting for MAIN MOTOR
Step
Action and Question
Yes
No
Parts below can be the source of this error (
Chapter 4 Disassembly and Assembly
)
• MAIN MOTOR
(p.279)
• HARNESS ASSY LVPS
• LVPS
(p.287)
• HVPS/MCU
(p.301)
1
MAIN Motor
1. Remove the Imaging Cartridge.
2. Close the COVER OPEN.
3. Turn on the main power.
4. Check for operating sound of the MAIN Motor.
♦
Does the MAIN Motor operate?
Go to Step 2
Go to Step 3
2
♦
Has the trouble been cleared?
Problem
solved
Go to Step 3
3
HARNESS ASSY LVPS (1)
1.
Remove the SHIELD PLATE LVPS.
(p.285)
2. Disconnect P/J41 from the LVPS.
(Refer to
“Connectors
(p.406)”
)
3. Disconnect P/J11 from the HVPS/MCU.
4. Check continuity between P/J41
↔
P/J11.
♦
Is there continuity in each wiring between P/J41
↔
P/J11?
Go to Step 4
Replace the
HARNESS
ASSY LVPS
4
HARNESS ASSY LVPS (2)
1.
Remove the SHIELD PLATE LVPS.
(p.285)
2. Disconnect P/J42 from the LVPS.
(Refer to
“Connectors
(p.406)”
)
3. Disconnect P/J10 from the HVPS/MCU.
4. Check continuity between P/J42
↔
P/J10.
♦
Is there continuity in each wiring between P/J42
↔
P/J10?
Go to Step 5
Replace the
HARNESS
ASSY LVPS
5
LVPS
1.
Replace the LVPS.
(p.287)
♦
Has the trouble been cleared?
Problem
solved
Go to Step 6
6
HVPS/MCU
1.
Replace the HVPS/MCU.
(p.301)
♦
Has the trouble been cleared?
Problem
solved
Replace the
MAIN
MOTOR
Table 3-61. Troubleshooting for MAIN MOTOR (continued)
Step
Action and Question
Yes
No
Summary of Contents for AcuLaser M4000N
Page 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 404: ...Confidential C H A P T E R 6 MAINTENANCE ...