EPSON EPL-N3000/AcuLaser M4000N
Revision C
Disassembly and Assembly
AcuLaser M4000N Unique Disassembly Procedures
387
Confidential
Installation
1.
Secure the ROS ASSY to the frame with the four screws (black, with collars,
8mm).
2.
Connect the connector of the HARNESS ASSY ROS to the board on the ROS
ASSY.
3.
Clamp the harness with the two cable clamps on the ROS ASSY.
4.
Secure the PLATE TIE FRONT to the frame tightly with the eight screws (silver,
6mm).
5.
Secure the harness to the PLATE TIE FRONT with the two clamps.
6.
Secure the DUCT VACUUM L/R with the screw (silver, with collars, 8mm).
7.
Secure the DUCT HIGH with the three screws (silver, with collars, 8mm).
8.
Install the DUCT FRONT, FAN SUB. (p.241)
9.
Install the COVER FRONT. (p.172)
10.
Install the COVER TOP, CONTROL PANEL (AcuLaser M4000N). (p.380)
11.
Install the 500 EXIT ASSY. (p.262)
12.
Install the COVER EXIT 500. (p.261)
13.
Install the COVER RIGHT. (p.168)
14.
Install the COVER LEFT. (p.169)
15.
Install the COVER REAR (AcuLaser M4000N). (p.379)
16.
Install the COVER REAR 500. (p.270)
C A U T I O N
Never give impact to the ROS ASSY with a screwdriver or the like.
C A U T I O N
As the board of the ROS ASSY is easily damaged, connect the
connectors while supporting the board by hand.
C A U T I O N
Always do installation work on a horizontal and level table.
C A U T I O N
Pay attention to the difference between the two types of screws and
use them at their correct positions respectively.
Summary of Contents for AcuLaser M4000N
Page 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 404: ...Confidential C H A P T E R 6 MAINTENANCE ...