4.8.2 500 EXIT ASSY
Removal
1.
Remove the COVER REAR 500. (p.270)
2.
Remove the COVER REAR. (p.167)
3.
Remove the COVER LEFT. (p.169)
4.
Remove the COVER RIGHT. (p.168)
5.
Remove the COVER EXIT 500. (p.261)
6.
Remove the SHIELD ASSY ESS. (p.294)
7.
Disconnect the connector (P/J29) of the HARNESS ASSY EXIT SNR from the
HVPS/MCU.
8.
Disconnect the connector (P/J103) of the MOTOR ASSY EXIT from the PWBA
EXIT MOTOR.
9.
Remove the five screws (silver, with flange, 8mm, 4 pcs., silver, 6mm, 1 pc.)
securing the 500 EXIT ASSY to the printer body.
10.
Remove the 500 EXIT ASSY. (p.262)
Installation
1.
Pass the harnesses of the MOTOR ASSY EXIT and SENSOR through the hole of
the frame.
2.
Install the 500 EXIT ASSY with the five screws (silver, with flange, 8mm, 4 pcs.,
silver, 6mm, 1 pc.).
3.
Connect the connector (P/J103) of the MOTOR ASSY EXIT to the PWBA EXIT
MOTOR.
4.
Connect the connector (P/J29) of the HARNESS ASSY EXIT SNR to the HVPS/
MCU.
5.
Install the SHIELD ASSY ESS. (p.294)
6.
Install the COVER EXIT 500. (p.261)
7.
Install the COVER RIGHT. (p.168)
8.
Install the COVER LEFT. (p.169)
9.
Install the COVER REAR. (p.167)
10. Install the COVER REAR 500. (
p.270
)
Figure 4- 73. 500 EXIT ASSY Removal
C A U T I O N
Pay attention to the difference between the two types of screws and
use them at their correct positions respectively.
JG3017EB
500 EXIT ASSY
PWBA EXIT MOTOR
SHIELD ASSY ESS
8)
6)
9)
7)
Summary of Contents for AcuLaser M4000N
Page 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 404: ...Confidential C H A P T E R 6 MAINTENANCE ...