EPSON EPL-N3000/AcuLaser M4000N
Revision C
Disassembly and Assembly
Option Duplex
349
Confidential
4.12.6 FAN DUPLEX
Removal
1.
Remove the COVER LEFT. (p.353)
2.
Remove the COVER TOP. (p.346)
3.
Disconnect the connector of the harness from the connector (P/J54) of the PWBA
DUPLEX.
4.
Disconnect the harness of the FAN DUPLEX from the hook of the COVER HSG
DUP.
5.
Remove the two screws (gold, tapping, 22mm) securing the FAN DUPLEX to the
COVER HSG DUP.
6.
Remove the FAN DUPLEX.
Installation
1.
Install the FAN DUPLEX to the COVER HSG DUP with the two screws (gold,
tapping, 22mm).
2.
Secure the harness of the FAN DUPLEX with the hook of the COVER HSG DUP.
3.
Connect the connector (P/J54) of the harness from the connector of the PWBA
DUPLEX.
4.
Install the COVER TOP. (p.346)
5.
Install the COVER RIGHT. (p.354)
Figure 4- 149. FAN DUPLEX Removal
C H E C K
P O I N T
Disassembly procedures for these parts are different between EPL-
N3000 and AcuLaser M4000N. For AcuLaser M4000N, see
4.14.11
FAN DUPLEX (AcuLaser M4000N)
(p.395)
.
C H E C K
P O I N T
Install the FAN DUPLEX with its label surface outside.
C H E C K
P O I N T
When installing the COVER TOP, match its positioning holes with
the bosses of the COVER HSG DUP.
C H E C K
P O I N T
When installing the COVER RIGHT, match its positioning holes
with the bosses of the COVER HSG DUP.
FAN DUPLEX
COVER HSG DUP
LABEL
JG3606AB
PWBA DUPLEX
5)
6)
3)
4)
Summary of Contents for AcuLaser M4000N
Page 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 404: ...Confidential C H A P T E R 6 MAINTENANCE ...