EPSON EPL-N3000/AcuLaser M4000N
Revision C
Disassembly and Assembly
Cover
170
Confidential
4.2.4 COVER TOP, CONTROL PANEL
Removal
1.
Remove the COVER REAR 500. (p.270)
2.
Remove the COVER REAR. (p.167)
3.
Remove the COVER LEFT. (p.169)
4.
Remove the COVER RIGHT. (p.168)
5.
Remove the COVER EXIT 500. (p.261)
6.
Remove the 500 EXIT ASSY. (p.262)
7.
Remove the two screws (silver, with a collar, 8 mm) securing the COVER TOP.
8.
Disengage the LEVER LINK from the boss on the COVER OPEN.
9.
Release the two hooks at the front of the COVER TOP from the COVER FRONT,
and remove and slightly separate the COVER TOP from the printer body.
10. Disconnect the connectors (P/J144, P/J411) of the SWITCH I/L ASSY from the
connectors of the frame.
11. Disconnect the connector (P/J1) of the CONTROL PANEL.
12. Release the harnesses of the SWITCH I/L ASSY and CONTROL PANEL from
the clamps.
13. Remove the COVER TOP.
14. Release the two hooks securing the CONTROL PANEL to the COVER TOP, and
remove the CONTROL PANEL.
Figure 4- 7. COVER TOP, CONTROL PANEL Removal
C H E C K
P O I N T
Disassembly procedures for these parts are different between EPL-
N3000 and AcuLaser M4000N. For AcuLaser M4000N, see
4.14.2
COVER TOP, CONTROL PANEL (AcuLaser M4000N)
(p.380)
.
C A U T I O N
Open the COVER OPEN and stretch the LEVER LINK first,
and then disengage the LEVER LINK from the COVER
OPEN.
The OPERATION PANEL mounted on the COVER TOP is
connected to the printer body with the connector. When doing
the following work, do not separate them too far.
JG3006EA
CONTROL PANEL
COVER OPEN
7)
10)
13)
8)
9)
11)
14)-1
14-2)
Summary of Contents for AcuLaser M4000N
Page 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 404: ...Confidential C H A P T E R 6 MAINTENANCE ...