3.2.18 Fuser Life
3.2.19 Maintenance unit Life (AcuLaser M4000N only)
Table 3-21. Troubleshooting for “Fuser Life”
Step
Action and Question
Yes
No
Parts below can be the source of this error (
Chapter 4 Disassembly and Assembly
)
•
FUSER ASSY
(p.253)
•
HARNESS ASSY FUSER
(p.251)
•
HVPS/MCU
(p.301)
1
FUSER ASSY
1. Replace the FUSER ASSY for a new one.
2. Excute the "Reset Fuser Counter" in the Reset
Menu.
♦
Does the error still occur?
Replace the
HVPS/MCU
Problem
solved
Table 3-22. Troubleshooting for “Maintenance unit Life”
Step
Action and Question
Yes
No
Parts below can be the source of this error (
Chapter 4 Disassembly and Assembly
)
• BTR ASSY
(p.254)
• KIT ROLL ASSY FEED (MP Cassette)
(p. 175, p. 213)
• KIT ROLL ASSY FEED (Cassette 1)
(p. 191, p. 226)
• GUIDE ASSY CRU R
(p.257)
• HVPS/MCU
(p.301)
1
Maintenance Unit
1. Replace the following parts.
BTR ASSY
KIT ROLL ASSY FEED x 2 sets
(MP Cassette and Cassette1)
2. Excute the "Reset Maintenance Counter" in the
Reset Menu.
♦
Does the error still occur?
Go to Step 2
Problem
solved
2
HVPS/MCU
1. Remove the BTR ASSY.
2. Remove the GUIDE ASSY CRU R.
♦
Is there continuity in each wiring of each harness?
Replace the
HVPS/MCU
Replace the
GUIDE ASSY
CRU R
Summary of Contents for AcuLaser M4000N
Page 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 404: ...Confidential C H A P T E R 6 MAINTENANCE ...