EPSON EPL-N3000/AcuLaser M4000N
Revision C
Troubleshooting
Troubleshooting for Individual Units
135
Confidential
3.4.27 CLUTCH PR-REGI
Table 3-86. Troubleshooting for CLUTCH PR-REGI
Step
Action and Question
Yes
No
Parts below can be the source of this error (
Chapter 4 Disassembly and Assembly
)
• CLUTCH PR-REGI
(p.319)
• OPTION 550 PAPER FEEDER
(p.303)
• 550 Paper Cassette
(p.191)
• PWBA FEEDER 550
(p.310)
• HARNESS ASSY CLSNR1
• HARNESS ASSY CLSNR2
• HARNESS ASSY FDR1
• HARNESS ASSY FDR2
• HVPS/MCU
(p.301)
• LVPS
(p.287)
1
Continuity of the HARNESS ASSY CLSNR1
1. Disconnect the P/J855.
(Refer to
“Connectors
(p.406)”
)
2. Disconnect the P/J854.
3. Check continuity between J855
↔
J854.
♦
Does each wiring between J855
↔
J854 have
continuity?
Go to Step 2
Replace the
HARNESS
ASSY
CLSNR1
2
Continuity of the HARNESS ASSY CLSNR2
1. Disconnect the connector P/J85 on the PWBA
FEEDER550.
2. Disconnect the P/J855.
3. Check continuity between J85
↔
J855.
♦
Does each wiring between J85
↔
J855 have
continuity?
Go to Step 3
Replace the
HARNESS
ASSY
CLSNR2
3
CLUTCH PR-REGI
1. Measure the resistance between P/J854-1
↔
P/J854-
2.
♦
Is the coil resistance of the CLUTCH PR-REGI
172
Ω
±
10% (20
°
C)?
Go to Step 4
Replace the
CLUTCH PR-
REGI
4
Continuity of the PWBA FEEDER550
1. Disconnect the connector P/J83 on the PWBA
FEEDER550.
2. Check continuity between the following terminals:
P83-3
↔
P85-3
♦
Is there continuity between P83-3
↔
P85-3?
Go to Step 5
Replace the
PWBA
FEEDER550
5
Continuity of the HARNESS ASSY FDR2
1. Remove the HARNESS ASSY FDR2.
2. Check the wiring between J2083
↔
J83 for
continuity.
♦
Is there continuity between J2083
↔
J83?
Go to Step 6
Replace the
HARNESS
ASSY FDR2
6
Continuity of the HARNESS ASSY FDR1
1. Remove the HARNESS ASSY FDR1.
2. Check the wiring between J20
↔
J2083 for
continuity.
♦
Is there continuity between J20
↔
J2083?
Go to Step 7
Replace the
HARNESS
ASSY FDR1
7
Power supply to the CLUTCH PR-REGI
1. Remove the Imaging Cartridge.
2. Measure the voltage between P20-10
↔
P20-9 on
the HVPS/MCU.
♦
24 VDC between P20-10
↔
P20-9?
Replace the
CLUTCH PR-
REGI
Go to Step 8
8
Continuity of the HVPS/MCU
1. Disconnect P/J10 from the HVPS/MCU.
2. Check continuity between P10-1
↔
P20-10.
♦
Is there continuity between P10-1
↔
P20-10?
Go to
3.4.1
LVPS
(p.111)
Replace the
HVPS/MCU
Table 3-86. Troubleshooting for CLUTCH PR-REGI
Step
Action and Question
Yes
No
Summary of Contents for AcuLaser M4000N
Page 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 404: ...Confidential C H A P T E R 6 MAINTENANCE ...