EPSON EPL-N3000/AcuLaser M4000N
Revision C
Adjustment
Firmware Update
403
Confidential
7
Perform the update
When the printer starts to receive the file or begins rewriting, the data LED
flashes and the message “
ROM P Writing
” appears on the LCD panel.
When the transfer is complete, the “Completion” window pops up. Click
[OK].
Confirm that both old and new firmware versions are displayed on the LCD
panel, and press the [
] button on the control panel.
The “Completion” window will be displayed when the data transfer is
finished. Click [OK].
8
Confirm the checksum
---
When the program update is finished, the checksum appears on the LCD
panel.
Confirm the checksum.
9
Reboot the printer
After confirming the data LED is turned off and the LCD panel displays
“
Ready
”, turn the printer power off and turn back on again.
Press [
].
The printer automatically reboots.
10
Print a status sheet
Print a status sheet.
Print a status sheet.
11
Check the firmware version on the
status sheet
Confirm that the firmware has been updated properly by comparing the
status sheet with the one printed in step 1. Refer to
“ 7.4.1 Status Sheet”
(p.430)
Confirm that the program firmware version has been updated correctly by
comparing the status sheet with that printed in step 1. Refer to
“ 7.4.1 Status
Sheet”
(p.430)
Procedure
Method 1
Method 2
(RCC)
(CRB)
Summary of Contents for AcuLaser M4000N
Page 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 404: ...Confidential C H A P T E R 6 MAINTENANCE ...