EPSON EPL-N3000/AcuLaser M4000N
Revision C
Disassembly and Assembly
Option Duplex
357
Confidential
4.12.12 SWITCH DUPLEX
Removal
1.
Remove the COVER LEFT. (p.353)
2.
Remove the COVER TOP. (p.346)
3.
Remove the PWBA DUPLEX. (p.347)
4.
Remove the one screw (silver, 6mm) securing the HARNESS ASSY DUP
EARTH.
5.
Remove the three screws (gold, tapping, 8mm) securing the BRACKET MOTOR
to the COVER HSG DUP.
6.
Remove the SPRING LATCH installed between the LEVER LATCH LEFT and
BRACKET MOTOR.
7.
Remove the BRACKET MOTOR mounted with the MOTOR DUPLEX and
SWITCH DUPLEX.
8.
Disconnect the HARNESS ASSY DUP COVER from the connector (P/J52) of the
SWITCH DUPLEX.
9.
Disengage the hooks of the SWITCH DUPLEX, and remove the SWITCH
DUPLEX from the BRACKET MOTOR.
Figure 4- 155. SWITCH DUPLEX Removal
C H E C K
P O I N T
When removing the BRACKET MOTOR, be careful not to
mislay the gears installed to the COVER HSG DUP.
When removing the BRACKET MOTOR, be careful not to
mislay the SPRING LATCH installed between the LEVER
LATCH LEFT and BRACKET MOTOR as the SPRING
LATCH comes off.
JG3617AB
SWITCH DUPLEX
BRACKET MOTOR
COVER HSG DUP
SPRING LATCH
HARNESS ASSY DUP EARTH
HARNESS ASSY DUP COVER
6)
7)
4)
5)
8)
Summary of Contents for AcuLaser M4000N
Page 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 404: ...Confidential C H A P T E R 6 MAINTENANCE ...