3.3.6 Full Stack Error/500 Paper Exit
Table 3-58. Troubleshooting for “Full Stack Error/500 Paper Exit”
Step
Action and Question
Yes
No
Parts below can be the source of this error (
Chapter 4 Disassembly and Assembly
)
•
SENSOR FULL STACK
(p.268)
•
ACTUATOR FULL STACK
(p.269)
•
HVPS/MCU
(p.301)
1
ACTUATOR FULL STACK
♦
Does the ACTUATOR FULL STACK in the paper
exit operate smoothly?
Go to Step 2
Replace the
ACTUATOR
FULL
STACK
2
SENSOR FULL STACK
1.
Replace the SENSOR FULL STACK.
(p.268)
.
♦
After the SENSOR FULL STACK is replaced, does
the problem still occur?
Replace the
HVPS/MCU
Problem
solved