EPSON EPL-N3000/AcuLaser M4000N
Revision C
Disassembly and Assembly
Xero
255
Confidential
4.7.10 CHUTE TRANSFR
Removal
1.
Remove the COVER REAR 500. (p.270)
2.
Remove the COVER REAR. (p.167)
3.
Remove the FUSER ASSY. (p.253)
4.
Remove the BTR ASSY. (p.254)
5.
Remove the FAN MAIN. (p.293)
6.
Release the hook of the CHUTE TRANSFER.
7.
Shift the CHUTE TRANSFER in the direction of the arrow and remove it from the
frame.
Installation
1.
Move the CHUTE TRANSFER in the direction opposite to the arrow, install the
CHUTE TRANSFER to the frame, and secure it with the hook.
2.
Install the FAN MAIN. (p.293)
3.
Install the BTR ASSY. (p.254)
4.
Install the FUSER ASSY. (p.253)
5.
Install the COVER REAR. (p.167)
6.
Install the COVER REAR 500. (p.270)
Figure 4- 68. CHUTE TRANSFR Removal
C A U T I O N
In the hole on the left side of the CHUTE TRANSFER, a screw need
not be tightened.
C A U T I O N
Pay attention to the difference between the two types of screws and
use them at their correct positions respectively.
JG3015EA
CHUTE TRANSFER
HOOK
NOT FIX THE SCREW
IN THIS HOLE
7)
6)