EPSON EPL-N3000/AcuLaser M4000N
Revision C
Disassembly and Assembly
Option OCT
368
Confidential
4.13.7 PWBA OCT
Removal
1.
Remove the COVER REAR. (p.362)
2.
Remove the COVER OCT. (p.364)
3.
To prevent the ACTUATOR FULL STACK from being damaged, remove the
ACTUATOR FULL STACK.
(p.367)
4.
Release the harnesses connected to the S/W REAR COVER from the clamps.
5.
Disconnect the harnesses from the connectors (P/J70, P/J71, P/J72, P/J73, P/J74,
P/J75) of the PWBA OCT.
6.
Remove the two screws (gold, tapping, 8mm) securing the PWBA OCT block to
the HOUSING OCT.
7.
Remove the PWBA OCT block.
8.
Remove the one screw (silver, 6mm) securing the PWBA OCT to the SUPPORT
OCT RIGHT of the PWBA OCT block.
9.
Remove the PWBA OCT.
Figure 4- 164. PWBA OCT Removal
C A U T I O N
In the following step, secure the PWBA OCT by hand when
disconnecting the harness connectors from the PWBA OCT.
PWBA OCT
GUIDE GROOVES
PWBA OCT BLOCK
70
P/J74
72
71
73
75
JG3808AB
SUPPORT OCT RIGHT
5)
6)
8)
7)