5.2 General Safetry Instructions for Ground Connection/
Safety Circuit
DANGER:
The work described in this
chapter must only be carried
out by trained service
technicians.
DANGER:
Safety devices must not be
changed or bridged.
DANGER:
Before starting the work,
disconnect the dispenser from
the mains supply and close
the water tap.
DANGER:
When carrying out disassemblies
at the boiler, there is the danger
of being scalded by hot water (see
chap. 'Disassembly of the boiler').
DANGER:
After the repair work ensure
that the overflow tray (1) and
the overflow hose (2) are
mounted correctly. (Fig. 1)
DANGER:
When carrying out any kind of
work, ensure that the earth
connectors are mounted
correctly in order to guarantee
faultfree ground connection.
DANGER:
All metal parts must be
connected with metal screws.
Beneath the screw head there
must be a lock washer. Fasten
the screws tightly (ground
connection).
WARNING:
The manufacturer cannot be
held liable or responsible
when other than original spare
parts are used for repair work.
WARNING:
Cable harnesses must not be
repaired, but must be replaced
completely.
WARNING:
When the front part has been
dismounted in the course of
repair processes, make sure
that the hose (1) is mounted
correctly into the outlet elbow
(2) when remounting it. (Fig. 2)
CAUTION:
In any case, observe the safety
instructions of each chapter.
Fig. 1
CAUTION:
When the work has been
finished, always carry out a
functional test.
CAUTION:
Make sure that all earthed
conductor connections are
connected and fastened tightly.
•
Ground connections are located at:
-
the housing cover (1x),
-
the right housing wall, (2x) at the top,
-
the left housing wall at the bottom,
-
the support of the safety thermostat
overflow,
-
the thermostat,
-
the fan,
-
the heating element,
-
the dry running protection
-
the power supply console, 2x
-
the plug for the pot carrier switch at the
right
-
the plug for heating plate connection at
the top.
2
1
1
2
Summary of Contents for Cafitesse 100
Page 4: ......
Page 6: ......
Page 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Page 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Page 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Page 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Page 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Page 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Page 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Page 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Page 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Page 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Page 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...