07.2004
5F - 10
Functions - Cooling System
Service Manual Cafitesse 100
Temperature sensor
•
The function of the temperature sensor in
combination with the microprocessor is
similar to that of a thermostat.
•
Temperature deviations at the cooling
compartment wall are transferred to the
sensor by means of thermal conduction.
Increasing or decreasing temperatures
result in a corresponding increase or
decrease of the sensor resistance (PTC).
•
This alteration results in a voltage change
in the control circuit which will be registered
by the microprocessor.
•
The microprocessor compares the data to
switch the cooling circuit on or off.
•
The correct function of the PTC sensor is
important for the correct function of the
cooling system.
•
In the case of improper cooling, the sensor
must be checked.
•
Alternatively, one of the following
procedures can be applied:
a) Comparative measurement old - new, at
the same temperature
b) Resistance measurement and
comparison with the value from the
diagram.
Due to self-heating, the measuring
current must not exceed 1 mA.
•
Formula for the resistance
R = 813 + (6.96xT) + (0.0208xTxT) Ohm
T = temperature of the sensor in °C
The formula is valid for -25 < T < 25 °C.
Resistance/temperature table
Normal R (Ohm)
Normal T (°C)
652
-25.0
700
-17.1
750
-9.3
800
-1.9
8130
850
5.2
900
12.1
950
18.6
1000
25.0
1050
31.2
•
Sensor tolerances
at an indicated temperature : +/- 5 Ohm
at an indicated resistance : +/- 0.7 °C
-25
-20
-15
-10
-5
0
5
10
15
20
25
3
0
3
5
600
700
800
900
1000
1100
Ω
°
C
Fig. 1
Summary of Contents for Cafitesse 100
Page 4: ......
Page 6: ......
Page 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Page 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Page 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Page 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Page 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Page 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Page 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Page 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Page 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Page 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Page 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...