3 - 10
Faults
Service Manual Cafitesse 100
07.2004
Fault
Possible cause
Remedy
1. Decalcify or adjust the hose.
2. Replace the flexy-pack.
3. Check if message "ERROR-last
dosing" is displayed by means of
service device 2. If no ERR is
displayed, proceed with step 4.
If ERR is displayed, proceed with 3a.
3a If not o.k., insert the flexy-pack in
accordance with instructions.
3b Replace the control unit (see chap.
5K.2).
4. See step 3.
5. Check the flow rate, check whether
the supply line is blocked.
6. Replace the control unit (see chap.
5K.2).
1. Insert the flexy pack-in accordance
with instructions, insert a new
package if necessary.
2. Disconnect ST08 from control unit.
Check LED.
If LED flashes: Replace the control
unit.
If LED does not flash: Replace
diode/transistor.
Check the 'empty' indicator and
replace it if necessary.
1. Bridge PINs 1 and 4 of Bu/St08:
Check LED.
If LED flashes: Defective transistor or
diode —> replace. If LED does not
flash: Defective control unit —>
replace.
Defective LED —> replace LED.
1. Ventilation hose in the
outlet elbow is blocked or
bent
2. Dosing system of flexy-
pack defective
3. Intervals of dosing pulses
out of tolerances
3a Dosing system of flexy-
pack or flexi-pack
incorrectly inserted
3b Error of control unit
4. Conduction through
concentrate coil out of
tolerances
5. Water level in the boiler
varies, insufficient supply
6. Control unit defective
1. Incorrect insertion of flexy-
pack
2. Transistor, diode in
screened coil, or control
unit defective
1. LED, phototransistor,
photodiode, or control unit
defective
Beverage strength
varies, irregular
concentrate dosing
"Empty" indicator
on, flexy-pack full
"Empty" indicator
off, but flexy-pack
empty
Summary of Contents for Cafitesse 100
Page 4: ......
Page 6: ......
Page 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Page 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Page 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Page 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Page 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Page 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Page 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Page 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Page 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Page 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Page 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...