3 - 8
Faults
Service Manual Cafitesse 100
07.2004
Fault
Possible cause
Remedy
3.2.3 Cooling System Malfunctions
Yellow LED on
operating panel is
flashing (short
flashing frequency),
insufficient cooling.
Temperature >11 °C
(51 °F)
The cooling system
does not run, the
yellow LED on the
control system is
off
The cooling system
does not run, the
yellow LED on the
control system is on
1. Power supply interrupted
or dispenser disonnected
from the mains supply for
a longer time
2. Flexy-packs' temperature
too high, was not thawed
in the refrigerator
3. Ventilating grid blocked
4. Heat sink or fan blocked
5. Fan defective
6. Ambient temperature too
high
7. Wrong tolerance of the
Peltier element
1. Break down of the fuse
F04 in the power supply
or of thermo fuse in the
transformer T01 (USA/
Can)
Transformer T01 or
control unit defective
1. Temperature sensor or
control unit defective
2. Peltier element defective
1. Check the power supply. The flashing
stops as soon as the correct
temperature has been reached (after
approx. 1 hour).
2. Replace the flexy-pack, follow filling
and thawing requirements.
3. Clean. Place the dispenser with a
distance to the wall of at least 5 cm
(2 in).
4. Clean.
5. Replace the fan (see chap. 5F.2).
6. Change the location of the dispenser.
7. Disconnect sensor plug ST05 from
the control unit and bridge PINs 1
and 2 of BU05. Measure the voltage
above the multiplier. If the measured
value is out of tolerance 0.1V <
value < 0.32V: Replace the Peltier
element.
1. Disconnet plug ST07 from the control
unit, replace the fuse, and check
transformer T01 for 11-14V at PIN 5
and 2 (see chap. 5K.2).
If 11-14V: Replace the control unit.
If not 11-14V: Replace transformer
and fuse.
1. Disconnect sensor Bu05 from the
control unit. Check if Bu06 carries
12 V at PIN 1 and 3.
If 12V: Replace the pipe.
If not 12V: Replace the control unit.
2. Disconnect the sensor plug ST05
from the control unit and bridge PINs
1 and 2 of BU05. Measure the
voltage above the multiplier. If the
measured value is out of the
tolerance 0.1V < value < 0.32V
:
Replace the Peltier element (see
chap. 5F.2).
Summary of Contents for Cafitesse 100
Page 4: ......
Page 6: ......
Page 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Page 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Page 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Page 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Page 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Page 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Page 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Page 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Page 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Page 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Page 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...