4 - 17
Programming
Service Manual Cafitesse 100
07.2004
Counter display mode
Input
or
↓
Display norm on
1=off 2=on
Display mode:
Display norm on:
The display is switched on during dispenser
operation.
Display indicates total amount of deliveries via
cup delivery button (110), or espresso delivery
button (120).
Display norm off:
The display is switched off, but the counter is
active.
Blocking of the beverage delivery at low
temperature
Input
or
↓
Temp block:##
1 = on 2 = off
The setting of "Temp. block:on" causes the block
of beverage deliveries as soon as the water
temperature in the boiler is < 80 °C (176 °F).
At the same temperature the yellow LED starts
flashing (long flash frequency).
If the water temperature in the boiler drops below
80°C (176°F) during a beverage delivery, the
dosing will be continued until the set delivery
volume is dispensed (delivery mode = portioned)
or until the push button is released (delivery mode
= continuous).
The default setting is 'Temp block: off', i.e. the
blocking of the beverage delivery at low
temperature is not activated.
Storing Values
Input
or
↓
Save values ?
1 = yes 2 = no
•
Press "1" to save all programmed values:
Values saved
SAT ready to use
Disconnect the service device and switch
on the dispenser
-or-
•
Press "2" to cancel (previously programmed
data remain valid):
Values not saved
SAT ready to use
If the programming procedure is cancelled or
stopped, the dispenser will be ready for
operation 25 seconds after switching on,
while previously programmed data remain
valid.
Summary of Contents for Cafitesse 100
Page 4: ......
Page 6: ......
Page 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Page 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Page 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Page 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Page 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Page 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Page 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Page 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Page 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Page 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Page 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...