07.2004
5F - 9
Functions - Cooling System
Service Manual Cafitesse 100
Temperature regulation
•
The electronic temperature sensor is
attached on the outside to the cooling
compartment base.
•
The cooling system is supplied by the
transformator T01. The secondary voltage is
rectified on the control board.
•
The sensor connects the cooling circuit
when the cooling compartment temperature
rises to approx. 2.8 °C and switches direct
current of 11–13V (depending on the mains
supply voltage) to the Peltier element.
•
Heat is conducted from the cooling
compartment through the heat sink and the
fan to the surrounding air. The fan is
connected to the mains supply and
operates permanently.
•
The sensor disconnects the cooling circuit
when the temperature decreases to approx.
1.7 °C. The temperature regulation ensures
that the concentrate is kept at a specific
temperature of +2 °C to +6 °C.
•
The cooling system can only be switched
off by disconnecting the dispenser from the
mains supply.
Ambient temperature
•
When the ambient temperature exceeds
32 °C sufficient cooling cannot be
guaranteed any more.
Error indications cooling compartment
temperature
•
see chapter Error Codes
Summary of Contents for Cafitesse 100
Page 4: ......
Page 6: ......
Page 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Page 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Page 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Page 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Page 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Page 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Page 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Page 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Page 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Page 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Page 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...