07.2004
5A - 12
Functions - Water System
Service Manual Cafitesse 100
8
7
5
Overflow safety thermostat
Disassembly:
•
Carry out the preparations for dismounting
the boiler cover (1). (Fig. 1)
(see chap. 5A.2)
•
Dismount the control (see corresponding
chapter) and remove the insulating foils (8).
(Fig. 2)
•
Loosen the fastening screw (2) and the
fastening washer (3) of the overflow safety
thermostat sensor (4). (Fig. 1)
•
Press the sensor (4) of the overflow safety
thermostat out of the support. (Fig. 1)
•
Disconnect the contacts (7) of the main
flexi cable harness from the overflow safety
thermostat (6). (Fig. 2)
•
Loosen the screws (5) of the overflow
safety thermostat (6). (Fig. 2)
Make sure that the lock washers do
not get lost.
•
Remove the overflow safety thermostat.
•
Remove the wiring towards the sensor of
the overflow safety thermostat from the
support at the boiler wall.
Assembly:
•
Assembly is done in the reverse order.
When mounting the wound wiring of
the overflow safety switch, unwind
approx. 3 windings from the sensor
side (upwards) and approx. 2 windings
of the thermostat side (downwards).
Mount the overflow safety switch and
the sensor. Place the wound wiring
behind the fastening strap of the boiler
insulation.
Make sure to suspend the insulation
foil (8) beneath the control. When
applying the I
2
C interface boards
espresso/café cool, place two small
insulating foils (9) between the
interface board and the overflow safety
thermostat. (Fig. 2, 3)
Fig. 1
1
Fig. 2
2
3
4
6
Fig. 3
9
Summary of Contents for Cafitesse 100
Page 4: ......
Page 6: ......
Page 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Page 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Page 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Page 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Page 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Page 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Page 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Page 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Page 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Page 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Page 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...