3 - 7
Faults
Service Manual Cafitesse 100
07.2004
The dispenser does
not heat up the
water
Water boils
(steam)
Low temperature
indicator does not
operate
Yellow LED flashing
(long flashing
frequency)
Delivery blocked
Fault
Possible cause
Remedy
4. Defective thermostat
5. Contacts of temperature
limiter open or defective
(–> dry running protection)
6. Contacts of overflow
safety thermostat open
7. Defective heating element
1. Thermostat switches off
too late – lime deposits in
sensor tube
2. Thermostat adjustment is
higher than required
3. Thermostat contacts are
fixed
1. Defective LED, control unit
or sensor
1. Water temperature in
boiler <80°C (176°F)
and 'Temp block=ON'
4. Check the connection with maximum
adjustments. If no connection:
Replace the thermostat (see chap.
5A.2).
5. Press Reset button. Check the
connection. If no connection:
Replace the temperature limiter.
Reset the dry running protection.
6. Sensor tube calcified or
reset the thermostat to zero (•) and
check the connection.
Decalcify the boiler
or
if connecting: Replace the thermostat,
reduce the adjustment of the
thermostat if required.
Press Reset button.
7. Check the heating element for
connection and short circuits, replace
the heating element if required (see
chap. 5A.2).
1. Decalcify the boiler.
2. Reduce the adjustment.
3. Reset the thermostat to zero (•) and
check for connection, replace the
thermostat if required.
1. Disconnect the sensor plug ST04
from the control and bridge PINs 1
and 2 of BU04.
LED flashing: Defective sensor —>
Replace the sensor.
LED not flashing: Defective LED or
control unit —> Replace LED —>
LED not flashing: Replace the
control unit.
1. Wait until the water in the boiler has
reached delivery temperature again.
If the LED does not stop flashing, see
'The dispenser does not heat up the
water'
Summary of Contents for Cafitesse 100
Page 4: ......
Page 6: ......
Page 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Page 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Page 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Page 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Page 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Page 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Page 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Page 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Page 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Page 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Page 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...