07.2004
5A - 11
Functions - Water System
Service Manual Cafitesse 100
3
4
6
5
7
Low temperature sensor
Disassembly:
•
Carry out the preparations for dismounting
the boiler cover. (see chap. 5A.2)
•
Disconnect the cable harness of the low
temperature sensor (1) from the control (2).
(Fig. 1)
•
Withdraw the low temperature sensor (3)
from the boiler cover (4). (Fig. 2)
Assembly:
•
Assembly is done in the reverse order.
When mounting the low temperature
sensor, ensure that the cable harness
(5) is placed between the guides (6) in
the boiler cover. Otherwise the float
switch function (7) may be affected.
Fig. 1
Fig. 2
2
1
Summary of Contents for Cafitesse 100
Page 4: ......
Page 6: ......
Page 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Page 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Page 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Page 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Page 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Page 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Page 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Page 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Page 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Page 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Page 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...