The following items will be required to install the ice maker kit.

1/4 inch copper or stainless steel supply line with shut off valve

• 

1/4 inch brass compression nut and ferrule (cooper tubing only)

• 

Freezer shelf (Some models not equipped with shelf). If your  model does not have 

• 

one, contact your dealer to order one.

The copper tubing and shut off valve are available in a kit from your local hardware or 
plumbing supply store. Coil enough tubing at the back of the unit to allow movement for 
cleaning.  

 

 

       

WARNING

To avoid electric shock, which can cause death or severe personal injury, 

• 

disconnect the refrigerator from electrical power before connecting a water 
supply line to the refrigerator.

Connect the ice maker to a potable water supply only.

• 

CAUTION

To Avoid Property Damage:

Copper tubing is recommended for the water supply line. Water supply tubing 

• 

made of 1/4” plastic is not recommended since it greatly increases the potential 

for water leaks. The manufacturer will not be responsible for any damage if plastic 

tubing is used for the supply line.
DO NOT

• 

 install water supply tubing in areas where temperatures fall below 

freezing.
Chemicals from a malfunctioning water softener can damage the ice maker. If the 

• 

ice maker is connected to softened water, ensure that the softener is maintained 
and working properly.

Summary of Contents for 242102400

Page 1: ...hock which can cause death or severe personal injury disconnect the refrigerator from electrical power before connecting a water supply line to the refrigerator Connect the ice maker to a potable water supply only CAUTION To Avoid Property Damage Copper tubing is recommended for the water supply line Water supply tubing made of 1 4 plastic is not recommended since it greatly increases the potentia...

Page 2: ...ectrical outlet 2 Remove ice tray rack from freezer some models 3 Remove spacer Remove freezer shelf some models by pushing shelf to left until right side of shelf comes free from holes Then slowly lift up and pull shelf free from holes on right side 4 Use a plastic putty knife to remove plugs and cover from inside freezer compartment Use a inch socket wrench or nut driver to remove harness connec...

Page 3: ...ck freezer panel just to the left of where the water inlet tube comes through See Figure 3 The harness connector is keyed so it will only fit one way Then mount Ice Maker to the two screws 3 you started earlier from Step 5 See Figure 4 Tighten screws Make sure water inlet tube is setting inside fill cup 7 Adjust leveling bracket 5 on Ice Maker 1 See Figure 5 When the gap between freezer wall and I...

Page 4: ...RFACE 4URN WATER SUPPLY AT SHUTOFF VALVE AND TIGHTEN ANY CONNECTIONS THAT LEAK 2ECONNECT REFRIGERATOR TO ELECTRICAL POWER SOURCE 4O TURN ICE MAKER ON LOWER WIRE SIGNAL ARM SIDE MOUNTED OR SET THE ICE MAKER S N FF POWER SWITCH TO THE hIv POSITION REAR MOUNTED Figure 1 Figure 2 WARNING 4O AVOID ELECTRIC SHOCK WHICH CAN CAUSE DEATH OR SEVERE PERSONAL INJURY DISCONNECT THE REFRIGERATOR FROM ELECTRICAL...

Page 5: ... sure the wire signal arm is in its down or ON position The ice maker will then produce more ice Occasionally shake the container to keep ice separated Keep the wire signal arm in its up or OFF position until the refrigerator is connected to the water supply or whenever the water supply is turned off The following sounds are normal when the ice maker is operating Motor running Ice loosening from t...

Reviews: