84
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 28
28 Install ED900 cover, end caps and
spindle caps
28.1 Install cover and end caps
28.1.1 Install covers.
1. Align cover with operator, press inward
until cover snaps into place.
CAUTION
Insure that all cables are in place
and secured as necessary.
TIPS AND RECOMMENDATIONS
Optional full width cover.
28.1.2 Install end caps.
1. Install ED900 operator end caps.
TIPS AND RECOMMENDATIONS
Program switch end cap; insertion
depth is adjustable to compensate
for minor tolerances is length of
operator cover.
Fig. 28.1.1 ED900 standard cover
Fig. 28.1.3 Cover and end cap installation
3
2
Fig. 28.1.2 ED900 operator end caps
2
End cap, program
switches
1
Standard cover
3
End cap, power
switch
3
2
1
2
End cap, program
switches
3
End cap, power
switch
1
ED900 standard
cover