55
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 15
15.8 Full width cover option – Install program switch, active door ED900
TIPS AND RECOMMENDATIONS
Active/inactive door orientation.
May be reversed from Fig. 15.8.1
orientation.
14.8.1 Install program switch.
1. Route program switch and cable into
active door ED900 housing.
2. Slide switch into slots in ED900 housing.
• Note orientation of switch in housing
(Fig. 15.8.3).
15.8.2 Connect program switch cable
wires to active door ED900
operator.
1. Connect program switch cable wires to
X1 terminal connector (Fig. 14.7.4)
Fig. 15.8.2 Program switch and cable
7
Program switch and
cable
10
Program switch
terminals
6
Slots for switch
7
Program switch and
cable
Fig. 15.8.3 Program switch installation
7
6
Fig. 15.8.4 Program switch cable
installation, active door ED900
7
Program switch
cable
Terminal
Wire color
Function
31
Brown
Automatic
34
Black
Permanent open
3
Red
0V
Fig. 15.8.5 Program switch functions
7
9
10
15.8.3 Program switch wiring.
Fig. 15.8.1 Program switch installation on active door
1
Single program
switch
2
Power switch
3031
32
33
34
335
3
Br
own
Black
R
ed
X1
7
Automatic
Close
Permanent open
1
2
Inactive door
Active door