24
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 10
10 ED900 door signage
Fig. 10.1.1 AUTOMATIC CAUTION DOOR decal
Fig. 10.1.2 ACTIVATE SWITCH TO OPERATE decal
Fig. 10.1.3 PUSH TO OPERATE, PULL TO OPERATE decals
10.1 Low energy operator
10.1.1 Overview
Signage and warnings are specified in ANSI /BHMA
A156.19, American National Standard for power assist
and low energy power operated doors.
10.1.2 All low energy doors.
1. AUTOMATIC CAUTION DOOR decal.
• All low energy doors shall be marked with signage
visible from both side of door with the words
"AUTOMATIC CAUTION DOOR".
• Signs shall be mounted 50" ± 12" from floor to
centerline of sign.
10.1.3 Knowing act switch used to initiate door operation.
1. ACTIVATE SWITCH TO OPERATE decal.
• When a knowing act device is used to initiate operation
of door operator, door shall be provided with sign on
each side of door where switch is operated with
message "ACTIVATE SWITCH TO OPERATE".
10.1.4 Push/Pull used to initiate door operation.
1. PUSH TO OPERATE, PULL TO OPERATE decals.
• When push/pull is used to initiate operation of door
operator, doors shall be provided with the message
"PUSH TO OPERATE" on push side of door and
"PULL TO OPERATE" on pull side of door.
CAUTION
DOOR
AUTOMATIC
DD0586-010
1
Activate Switch to
Operate
DD0758-010
ACTIVATE SWITC
H
TO OPERATE
DD0758-010
1
2
Push to Operate
3
Pull to Operate
DD0762-010
PUSH
TO OPERATE
2
DD0762-020
PULL
TO OPERATE
3
10.1.5 Knowing act:
ANSI/BHMA standard A159.19 definition.
Any conscious action with the expected result of
opening a door. This includes but is not limited to::
• Wall or jamb mounted contact or non contact
switches such as push plates.
• The action of manually opening (pushing or pulling)
a door.
• Controlled access devices such as keypads, card