38
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 13
13.3 Installation templates, double doors
Fig. 13.3.1 Pull version, mounting on hinge side, Professional cover, standard axle extension
Inches
mm
Inches
mm
Inches
mm
Inches
mm
Axle extension
Standard
3/4
20
1 3/16
30
2 3/8
60
A
7/8
22
1 5/8
42
2
52
3 1/4
82
Inches
mm
Inches
mm
Pivot pin
1/2
12.5
1
25
B
3/4
19
1 1/4
32
Reveal depth
maximum:
5/8”
[15]
5 7/8”
[150]
± 1 1/16” [30]
2 3/8” [61]
5 1/8” [130]
2 3/4” [70]
5 7/8”
[150]
5/8”
[15]
Minimum 55 1/8” [1400], 57 1/16” [1450] with ESR
Drilling template: short pivot pin 1/2” [12.5]
Center of
operator axle
1 3/4” [45]
5 7/8” [150]
4 3/16” [106]
1 1/4” [31.5]
2 1/2” [63]
3 15/16”
[100]
4 3/4”
[120]
4 3/4”
[120]
4 3/4”
[120]
3 3/4”
[95]
17 3/4”
[451]
Minimum 55 1/8” [1400], 57 1/16” [1450] with ESR
Upper edge of door panel
Cable entry location on either the left or right side.
17 3/4”
[451]
5 7/8” [150]
6 1/8”
[155]
4 3/16” [106]
3/8” [9]
1 3/4” [45]
6 1/8”
[155]
Drilling template: long pivot pin 1” [25]
Center of
operator axle
1 3/4” [45]
5 7/8” [150]
4 3/16” [106]
1 1/4” [31.5]
2 1/2” [63]
3 15/16”
[100]
4 3/4”
[120]
4 3/4”
[120]
4 3/4”
[120]
3 3/4”
[95]
Ø 1/4”
[6,6]
17 3/4”
[451]
Minimum 55 1/8” [1400], 57 1/16” [1450] with ESR
Upper edge of door panel
Cable entry location on either the left or right side.
17 3/4”
[451]
5 7/8” [150]
6 1/8”
[155]
4 3/16” [106]
3/8” [9]
1 3/4” [45]
6 1/8”
[155]
1 1/4”
[32]
11/16”
[19]
3 15/16”
[100]
4 3/4”
[120]
4 3/4”
[120]
4 3/4”
[120]
3 3/4”
[95]
Ø1/4”
[6,6]
3 15/16”
[100]
4 3/4”
[120]
4 3/4”
[120]
4 3/4”
[120]
3 3/4”
[95]
Ø1/4”
[6,6]
A+B+10
Ø1/4”
[6,6]