42
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 14
14.1 Remove mounting plate from each ED900 operator
Fig. 14.1.2 Mounting plate removed from ED900 operator
14.1.1 Remove 115 Vac plug from
receptacle.
1. Remove 115 Vac plug (
5
) from its
receptacle (
6
).
14.1.2 Remove mounting plate from
ED900 operator.
1. Loosen all eight captive ED900 M6 socket
head cap screws (SHCS) using a
5 mm hex T-handle.
TIPS AND RECOMMENDATIONS
Insure all eight fasteners are free
of the mounting plate.
2. Remove operator from mounting plate.
TIPS AND RECOMMENDATIONS
Guide pin resistance may require
screwdriver to start operator
removal from end of mounting
plate (Fig. 14.1.3).
Fig. 14.1.1 115 Vac plug removal
1
ED900 operator
2
Mounting base
3
M6 x 20 SHCS
4
M6 x 10 SHCS
5
Guide pin
6
115 Vac plug
2
3
3
4
4
1
5
6
5
115 Vac plug
6
115 Vac socket
5
6
5
6
14 ED900 operator and mounting plate
preparation