56
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 15
15.9 Full width cover option – 115 Vac pair power cable connections
Fig. 15.9.2 ED900 115 Vac pair power cable – inactive door
1
ED900 115 Vac plug
from 115 Vac socket,
female connection
2
ED900 power
supply circuit board
socket, male
connection
3
ED900 power
supply 115 Vac plug,
male connection
4
ED900 power
printed circuit board
socket, female
connection.
5
115 Vac pair power
cable plug, male
connection
15.9.1 Inactive door
1. Insert 115 Vac interconnecting cable plug
(
5
) into ED900 power supply circuit board
socket (
4
) (Fig.15.9.2).
1
3
Fig. 15.9.1 Inactive door cables
3
115 Vac interconnect
cable plug, male
connection
Fig. 15.9.4 ED900 115Vac pair power cable
– active door
6
7
6
ED900 power cord,
male connection
7
115 Vac pair power
cable plug, female
connection
7
Fig. 15.9.3 Active door cables
7
115 Vac pair power
cable plug, female
connection
1
2
3
4
5
4
5
4
15.9.2 Active door.
1. Insert 115 Vac interconnecting cable plug
(
7
) into ED900 power cord socket
(6
)
(Fig.15.9.4).