18
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 6
6 Technical data
Maximum wire size
Connector plug
screw size
16 AWG
1/16”
Door
status
X7
97,98,99
Sr
parameter
Door closed
Door open
Door closed, locked
Com, N.O., N.C.
contacts
6.1.5 Integrated functions.
Hold open time:
Automatic opening
dd
parameter
0 to 30 s
NIght / bank
dn
parameter
0 to 30 s
Manual opening
do
parameter
0 to 30 s
Door blocking
behavior
hd
parameter
Automatic, manual
door modes
Electric strike
delayed opening for
locking mechanism
Ud
parameter
0 to 4 s
Locking
device
feedback
X3
43, 3
Motor lock
Wind load control,
maximum
Fo, Fc
parameters
33.7 lb f
150 N
Voltage independent
braking circuit
Chapter 21
Adjustable with
potentiometer
LED status indicators
Chapter 8
Green
Red
Yellow
24 Vdc power
Error codes
Service interval
Program and Exit
Only switches
Chapter 8
Auto, Close, Open
Exit only; Off, On
User interface
Chapter 8
4 button keypad,
2 digit display
Firmware update
Appendix C
Firmware update
TMP, temperature
management program
Overload protection
IDC, initial drive control
Driving phase optimization
Cycle counter
CC
parameter
0 to 1,000,000
Power assist function
hA, hF, hS
parameters
Drive support for
manual opening of
door
Push & go function
PG
parameter
Auto opening of
door at 4° open
6.1 ED900 Technical data
6.1.1 Required operating conditions.
Ambient temperature
5 to 122 °F
Suitable for dry
rooms only
Relative air humidity:
93% maximum, non-condensing
Power supply
115 Vac ±10%, 50/60 Hz
6.6 A maximum
Branch circuit
protection (provided
by others)
15 A maximum,
dedicated branch circuit
Protection class
NEMA 1
Power wiring:
black, white, bare
copper (ground)
12 AWG
maximum
Operating noise
Maximum 50 db(A)
6.1.2 General specifications.
Operator dimensions
(W x H x D)
27" standard cover
27" x 2 3/4 x 5 1/8",
[685 x 70 x 130 mm]
Operator weight
26.5 lb [12 kg]
Maximum door
opening angle
95 to 110° depending on installation type
6.1.3 Inputs
Maximum wire size
Connector plug
screw size
16 AWG
1/16”
Activation
inputs
X4*
Interior, exterior
N. O. contact
Safety
sensors
X5
Swing, approach
sides
Night-bank
(intercom
system)
X10
57,
57a
8-24 Vdc/Vac +5%
Night-bank
(key switch)
X1
35, 3
d2
parameter
Configure for N.O.
or N.C. contact
Deactivation
of drive
function
X6
4, 4a
d1
parameter
Configure for N.O.
or N.C. contact
6.1.4 Outputs
TIPS AND RECOMMENDATIONS
• *
X4
:
terminal board numbers, reference
Chapter 9, System accessories.
• Parameters, reference Chapter 22.