background image

BL-200 Electromagnetic Lock Installation Instructions

Dimensions

Specifications

+

-

+

-

Power Supply

   15%

DC 12V / DC 24V

BL-200 

Notes

Operation Delay Time

Operation temperature

Accessories

1.Suitable for in-swing door or 90  doors

2.Built-in push button and power indicator light.

Adjustable door opening time (0~9 seconds.)

3.Build-in delay time and lock monitor output.

4.Armature with handle design.

5.Standalone operation when power is on and it does

not need to be controlled by proximity reader.

6.Install at the center of the door leaf to prevent

deformation whenever it is locked or unlock.

Page1

    5%

Hall Effect Sensor

450mA / 12VDC  235mA / 24VDC

Out-swing door and In-swing door

600lbs

The warranty is 1 years under normal circumstances

N. O / N. C

0 sec.

2.5sec.

5sec.

9sec.

Application

Holding forces

Warranty

Weight

3kg

Current

Monitor Output

Unit: mm

Plate X1

5X32Screw  X9

Model

Item 

Features

Lock Control - 

Kouterbaan

 

63

 - 1840 Malderen - Belgium - Tel.  +32 52 57 43 02 - [email protected] - www.lockcontrol.be

BL-200

 - 10

  BL-200

 - 20

 

12

00lbs

35˚C +-  5˚C  (30˚C room temperature)

8

kg

1

3kg

Length  

0,3m

1m

2m

Summary of Contents for BL-200

Page 1: ... does not need to be controlled by proximity reader 6 Install at the center of the door leaf to prevent deformation whenever it is locked or unlock Page1 5 Hall Effect Sensor 450mA 12VDC 235mA 24VDC Out swing door and In swing door 600lbs The warranty is 1 years under normal circumstances N O N C 0 sec 2 5sec 5sec 9sec Application Holding forces Warranty Weight 3kg Current Monitor Output Unit mm P...

Page 2: ...nd P S Points for external door open button Both built in and external door open buttons are able to be used at the same time Please refer to the diagram above 2 Door Lock status N O N C as Relay output Maximum load of 1A 24VAC 3 Indicator light is green when the door is locked or else the door did not close tight Attention Fig1 0 0sec 2 5sec 5 0sec 9 0sec ON 1 2 N C COM N O P S V V Control Panel ...

Page 3: ... screws to screw the handle onto the appropriate position of the installation holes when D is pulled out Please refer to Fig 7 Do not screw tight as to adjust both handle and body lock positions well by closing the door for several times to make sure both of them are matched Screw the remaining three screws when they are matched Screws Screws Adjusting to the right and left Fig5 Fig6 Fig7 Fig8 P L...

Page 4: ...if the voltage is correct 2 Check if the setting of voltage is correct 3 Check if the magnetic lock and armature are engaged lightly Indicator light is unable to show green light when door is closed Maintenance of the magnetic lock 1 Any dust or rust should be removed regularly 2 Lubricant should be apply on the magnetic lock to avoid any rust depending on the environment it is installed such as a...