73
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 22
Fig. 22.1.5 T275/Arm with CPD lever and track
22.1.7 Configuration parameters, detail.
Fig. 22.1.4 T/Arm with track
Fig. 22.1.6 J/Push arm
Fig. 22.1.7 J8/Deep reveal push arm
Parameter and value
range, factory setting
=
bold
.
Parameter description
1
0 - 2
0
Installation type
0
Pull
• Arm with track (Fig. 22.1.4).
• Arm and CPD lever with track
(Fig. 22.1.5).
Wall mounting on swing (hinge)
side.
1
Push
• Standard push arm
(Fig. 22.1.6)
Wall mounting on approach
(non-hinge) side.
2
Push
• Arm with track (Fig. 22.1.4).
• Arm and CPD lever with track
(Fig. 22.1.5).
Wall mounting on approach
(non-hinge) side.
2
ED900
-3 to 29
0
Reveal depth
0
Reveal is set in increments of
10 mm (3/8"), "3" = 30 mm (1 1/8")
• ED900: [-30 to 290 mm]
-1 3/16" to 11 13/32"
If using arm with CPD lever
(Fig. 22.1.5), approximately
1 3/16" [30 mm] must be
deducted from actual reveal.
3
Tb
ED900
7 to 12
12
Door width
10
Door width is set in increments of
100 mm (4"),;"9" = 900 mm (35.4").
• ED900: [700 - 1219] 28" - 48"
22.1.9 Arm with track – push installation
[Application specific].
1. For doors without fire or smoke detection
requirements.
2. Maximum reveal depth of 2 3/8" [60].
3. Maximum opening width at a reveal depth of
2 3/8"[60] is reduced to 95 degrees.
22.1.8 CPD arm and lever; rd parameter adjustment.
• Value of parameter
rd
must be reduced by 3/16" [30]
when using the arm with CPD lever in a pull
installation.
• Example: ED900 with arm and CPD lever in pull
installation with reveal of 30 mm (1 1/8").
Parameter rd setting = 0 (Reveal of 30 mm - 30 mm).
4
0 to 4
0
Door type
0
Single door
1
Double door
• Overlapping door (with
astragal)
• Active door operator.
2
Double door
• Overlapping door (with
astragal)
• Passive door operator.
3
Double door
• Edgeless door (no astragal)
• Active door operator.
4
Double door
• Edgeless door (no astragal)
• Passive door operator.