background image

 

 

 

Features 

·

 

Door Relay output 

·

 

Status

 transistor output 

·

 

Aux

  transistor output 

·

 

Door Contact input  

·

 

Exit Button input 

·

 

INSTALLER

 code for programming  

·

 

MASTER

 code for arming/disarming 

·

 

USER

 codes for door opening 

·

 

Door Alarm

 indication 

·

 

Option: 

Timed Lock-out

 after three wrong codes  

·

 

Option: 

Access only when Disarmed

  

·

 

Programmable length of codes 

·

 

User indexing for easy administration of codes 

·

 

Nonvolatile memory 

·

 

Keypad with backlight  

·

 

Door Bell key 

·

 

Three LEDs and buzzer 

·

 

Tamper

 contacts 

·

 

Outdoor operation (IP65) 

Electronic Code Lock 

SL2000E v1.2 

Rev.A 

Summary of Contents for SL2000E

Page 1: ...sarming USER codes for door opening Door Alarm indication Option Timed Lock out after three wrong codes Option Access only when Disarmed Programmable length of codes User indexing for easy administration of codes Nonvolatile memory Keypad with backlight Door Bell key Three LEDs and buzzer Tamper contacts Outdoor operation IP65 Electronic Code Lock SL2000E v1 2 Rev A ...

Page 2: ...he Bell key is pressed for a moment or the key is pressed and held down longer then half a second the Aux output goes steady on shorts to supply minus the Aux output remains in this condition as long as the Bell or key is being pressed The Aux output can be also activated when Door Alarm is active The code lock indicates the Door Alarm through pulsed modulation of the Aux output Thanks to this fea...

Page 3: ...will be disabled for both all USER codes and Exit Button unless the SL2000 will be switched to Disarmed mode Arming and Disarming of the Code Lock In normal operation mode the SL2000 may work either in the Armed or Disarmed mode The Armed mode is signalled by LED ARMED red whereas the Disarmed mode is signalled by LED DISARMED green The actual operating mode of a lock is also indicated on the Stat...

Page 4: ...and is successfully accomplished the unit generates three series of two beeps Old MASTER Code New MASTER Code This command erases the old MASTER code and program new MASTER code If command is successfully accomplished the unit generates three series of two beeps Bell Key A single short press of this key activates the Aux output and internal buzzer for a time of 2 3 seconds The indication on Aux ou...

Page 5: ...e code lock generates the three series of two beeps then ends the Memory Reset procedure and switches to normal working mode Meaning of the configuration parameters C1 C10 C1C2 Open Delay specifies the time delay from a moment when access is granted to a moment when Door Relay will be activated It can be programmed from 00 to 99s default 04 C3C4 Lock Activation Time specifies the time for which Do...

Page 6: ...the Memory Reset procedure comes to an end all codes are set to default values see section Default Codes Example The following digits C1 C10 were entered during the Memory Reset procedure 0 1 0 2 3 3 1 0 2 3 This sequence sets the following options Open Delay 01 second Lock Activation Time 02 seconds Time for Door Closing 33 seconds Reprogramming of the MASTER code disabled Reprogramming of the IN...

Page 7: ...e adequate wire gauge to guarantee that the voltage dropout between the power supply and the DC input of SL2000 will not exceed 1V in the worst case It is recommended to supply door release device e g door strike or magnet lock and SL2000 from separate power supply but when both code lock and door release device are supplied from the same power source you must use separate pairs of cable to supply...

Page 8: ...Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 Page 8 of 11 ...

Page 9: ...Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 Page 9 of 11 ...

Page 10: ...ignments Label Wire colour Description 12V Red Supply input plus GND Black Supply input minus Status Output Green Status transistor output max current sink 1 0A 16V DC AUX Brown Aux transistor output max current sink 1 0A 16V DC TMP A Grey Tamper contact A NC max 50mA 24V TMP B Yellow Tamper contact B NC max 50mA 24V Exit Button Blue Exit Button input NO type Door Contact White Green Door Contact ...

Page 11: ...ease of the product Contact Roger sp j 82 400 Sztum Gosciszewo 59 Tel 48 55 272 01 32 Fax 48 55 272 01 33 Technical support PSTN 48 55 267 01 26 Technical support GSM 48 664 294 087 e mail biuro roger pl The symbol of a crossed through waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this ...