background image

Security Locks SL2000E v1.2 EN Rev.A.doc 

 

2011-09-01 

 

Page 

5

 of 

11

 

 

 

[#]  

 

 

 

-

 Exit from the Installer Programming mode 

 
When the code lock accepts the new USER code it generates two series of two beeps (** **). Any attempt to 

program a USER code which already exists in memory or to program it with a code length bigger then 

programmed during 

Memory Reset

 will cause the programming error signalled by the long acoustic beep.  

Configuring the SL2000 ( Memory Reset) 

In order to configure the SL2000 you must perform the 

Memory Reset

 and then enter sequentially 10 digits 

(called 

C1-C10

) which will configure the unit for individual installation. After the 

Memory Reset

 the entire 

contents of the code lock memory is erased (including all codes) and initialized with 

Default (Factory)

 settings. 

These values  
 
In order to perform 

Memory Reset

 do the following steps: 

·

 

Turn off the power supply 

·

 

Connect 

Reset

 wire (Brown-Yellow) to supply plus 

·

 

Turn on the power supply 

·

 

Wait till the moment when device will sound three series of two beeps (** ** **) - this signal indicates that 

SL2000 erased memory and restored default configuration settings 

·

 

Disconnect 

Reset

 wire (Brown-Yellow) from supply plus 

·

 

Enter sequentially ten digits C1-C10 

·

 

After the last digit is entered the code lock generates the three series of two beeps (** ** **) then ends 
the 

Memory Reset

 procedure and switches to normal working mode. 

Meaning of the configuration parameters: C1-C10 
C1C2

:  

Open Delay

, specifies the time delay from a moment when access is granted to a moment when 

Door 

Relay

 will be activated. It can be programmed from 00 to 99s (default: 04). 

C3C4

:  

Lock Activation Time

, specifies the time for which 

Door Relay

 will be activated when access is granted. 

It can be programmed from 00 to 99s (default: 04). 

C5C6

Time for Door Closing

, specifies the time within which door must be closed. It can be programmed from 

00 to 99s, the 00 value sets unlimited time for closing (default: 09). 

C7

:  Enables or disables of reprogramming of the MASTER and INSTALLER codes, enter 0-3 (default: 0). 

Value 

Reprogramming of the MASTER code 

Reprogramming of the INSTALLER code 

Enabled 

Enabled 

Disabled 

Enabled 

Enabled 

Disabled 

Disabled 

Disabled 

C8

:  

Enabling and disabling 

Option 1

 and 

Option 2

, enter 0-3 (default:0). 

Value 

Option 1 

Option 2 

Disabled 

Disabled 

Enabled 

Disabled 

Disabled 

Enabled 

Enabled 

Enabled 

Option 1: Timed Lock-out 

Note: If 

reprogramming

 of a given code is disabled the SL2000 allows you a single attempt only to program of 

the given code. Once the code is programmed, you will not be able to change it unless the 

Memory Reset

 is 

carried out

.

 Use this function to disable the end user to change your MASTER and INSTALLER code 

Summary of Contents for SL2000E

Page 1: ...sarming USER codes for door opening Door Alarm indication Option Timed Lock out after three wrong codes Option Access only when Disarmed Programmable length of codes User indexing for easy administration of codes Nonvolatile memory Keypad with backlight Door Bell key Three LEDs and buzzer Tamper contacts Outdoor operation IP65 Electronic Code Lock SL2000E v1 2 Rev A ...

Page 2: ...he Bell key is pressed for a moment or the key is pressed and held down longer then half a second the Aux output goes steady on shorts to supply minus the Aux output remains in this condition as long as the Bell or key is being pressed The Aux output can be also activated when Door Alarm is active The code lock indicates the Door Alarm through pulsed modulation of the Aux output Thanks to this fea...

Page 3: ...will be disabled for both all USER codes and Exit Button unless the SL2000 will be switched to Disarmed mode Arming and Disarming of the Code Lock In normal operation mode the SL2000 may work either in the Armed or Disarmed mode The Armed mode is signalled by LED ARMED red whereas the Disarmed mode is signalled by LED DISARMED green The actual operating mode of a lock is also indicated on the Stat...

Page 4: ...and is successfully accomplished the unit generates three series of two beeps Old MASTER Code New MASTER Code This command erases the old MASTER code and program new MASTER code If command is successfully accomplished the unit generates three series of two beeps Bell Key A single short press of this key activates the Aux output and internal buzzer for a time of 2 3 seconds The indication on Aux ou...

Page 5: ...e code lock generates the three series of two beeps then ends the Memory Reset procedure and switches to normal working mode Meaning of the configuration parameters C1 C10 C1C2 Open Delay specifies the time delay from a moment when access is granted to a moment when Door Relay will be activated It can be programmed from 00 to 99s default 04 C3C4 Lock Activation Time specifies the time for which Do...

Page 6: ...the Memory Reset procedure comes to an end all codes are set to default values see section Default Codes Example The following digits C1 C10 were entered during the Memory Reset procedure 0 1 0 2 3 3 1 0 2 3 This sequence sets the following options Open Delay 01 second Lock Activation Time 02 seconds Time for Door Closing 33 seconds Reprogramming of the MASTER code disabled Reprogramming of the IN...

Page 7: ...e adequate wire gauge to guarantee that the voltage dropout between the power supply and the DC input of SL2000 will not exceed 1V in the worst case It is recommended to supply door release device e g door strike or magnet lock and SL2000 from separate power supply but when both code lock and door release device are supplied from the same power source you must use separate pairs of cable to supply...

Page 8: ...Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 Page 8 of 11 ...

Page 9: ...Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 Page 9 of 11 ...

Page 10: ...ignments Label Wire colour Description 12V Red Supply input plus GND Black Supply input minus Status Output Green Status transistor output max current sink 1 0A 16V DC AUX Brown Aux transistor output max current sink 1 0A 16V DC TMP A Grey Tamper contact A NC max 50mA 24V TMP B Yellow Tamper contact B NC max 50mA 24V Exit Button Blue Exit Button input NO type Door Contact White Green Door Contact ...

Page 11: ...ease of the product Contact Roger sp j 82 400 Sztum Gosciszewo 59 Tel 48 55 272 01 32 Fax 48 55 272 01 33 Technical support PSTN 48 55 267 01 26 Technical support GSM 48 664 294 087 e mail biuro roger pl The symbol of a crossed through waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this ...

Reviews: